Insert the programming module
when the controller is off
.
On activation display 1 shows
memo
and display 2 show
----
(
Only if the correct values are saved in the program-
ming module
). By pressing the
key display 2 shows
Load
, then confirm using the
FNC
key. The controller loads
the new data and starts again.
• With the controller not connected
to power supply
.
The programming module is equip-
ped with an internal battery with an
autonomy of about 1000 uses.
Insert the programming module
and press the programming button .
When writing the parameters, the led turns red and on
completing the procedure it changes to green. It is possible
to repeat the procedure without any particular attention.
Updating programming module
To update the programming module values, follow the proce-
dure described in the first method, setting display 2 to
----
so
as not to load the parameters on controller
1
.
Enter configuration level and change at least one parameter.
Exit configuration. Changes are saved automatically.
7.9
Loading default values
This procedure allows to restore factory settings of the
instrument.
1
If on activation the controller does not display
memo
it means no data
have been saved on the programming module, but it is possible to
update values.