WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. September, 2016
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Volta 4.5” LED - Downlight Round Trim
R4RD1T, R4RD2T, R4RD1L, R4RD2L
4. Replace the LED module (For Spot Beam)
a. Remove trim from the trim assembly first, then the trim assembly from
the ceiling or fixture aperture (See FIG.19).
b. To remove the invisible trim assembly, use the Philips head screw driver
to unlock horizontal lock, then use the flat head screw driver to release the
spring tab on aperture ring (See FIG.20).
c. Remove cap and disconnect wire connector and safety cable (See FIG.21).
d. Unlock and remove the optical cartridge and lens (See FIG.18).
e. Unscrew and remove the LED holder (See FIG.24).
f. Remove and discard the LED module from the heat sink.
g. Coat the heat paste (by others or call the factory) on the back of the new
LED module, then mount the LED onto the LED holder. Make sure LED
positive matching the holder positive. (See FIG.25)
h. Place back the LED holder on the heat sink by tightening two screws.
i. Lock the optical cartridge with lens on the heat sink. (See FIG.18)
j. Connect power connector and safety cable, then reinstall the trim assembly
and trim inside fixture to complete.
Heatsink
Heatsink
LED
LED
LED Holder
LED
Holder
Optical
Lens
Optical
Cartridge
Screws
Screws
FIG. 24
FIG. 25