3 - 2
MAINTENANCE
APRIL 2021
32DFR108.C
FR2SS-SERIES SERVICE MANUAL
B.
DAILY INSPECTION
Check ramp daily, following the Daily Inspection outlined in
Table 3-1
. Meet all inspection criteria before allowing pas-
sengers on ramp.
TABLE 3-1: DAILY INSPECTION
INSPECTION POINT
CHECK
Ramp controller
•
Power ON/OFF switch operates correctly.
•
Power On indicator illuminates when Power ON/OFF switch is ON.
•
DEPLOY and STOW switches operate correctly.
•
No unusual noises or erratic movements when ramp is deploying or stowing.
Ramp and
surrounding area
Vestibule area is free of loose objects, actuator drive arms and trim pockets are
free of debris.
Ramp non-slip
surfaces
•
Surface is clean and free of slippery or sticky substances that could compro-
mise user safety.
•
Surface is intact and secure, and loose edges, if present, cannot create a
stumbling hazard.
END OF TABLE
C.
MAINTENANCE SCHEDULE
Regular maintenance and inspection of the Ricon FoldOver ramp provides optimum performance and reduces the need
for repairs. Maintain the ramp as directed in
Table 3-2
. Perform ramp maintenance more frequently during heavy use
(more than 20 cycles per day).
CAUTION!
~ This Ricon Product Is Complex ~
Required warranty period maintenance and repairs must be done at a Ricon dealer or
trained and qualified service technician. Improper maintenance, use of non-Ricon
replacement parts, or product modification will void warranty and can result in unsafe
operating conditions. We recommend that a Ricon dealer or trained and qualified service
technician continue maintenance inspections when warranty ends.
TABLE 3-2: MAINTENANCE SCHEDULE
INSPECTION POINT
ACTION
– 6,000 MILE INSPECTION –
Hydraulic fluid leaks
Check all hoses and fittings; check fluid level. Tighten, fill, or replace as necessary with
Texaco 01554 Aircraft Hydraulic Oil or equivalent U.S. mil spec H5606G fluid.
Setscrews
Check for loose or missing setscrews at these locations:
•
Driveshaft couplers (2 x 4 ea)
•
Sensor target (1 ea)
•
Pillow blocks (2 x 2 ea)
Tighten, or replace, as necessary.
Drive arm
T-nuts
Check for looseness; tighten as necessary; apply thread locker (Loc-tite
blue), as neces-
sary. Refer to
Figure 3-4
for drive arm hardware configuration.
Ramp interior
(for debris)
Check area below floor plate, and remove any accumulated dirt or debris.