4 - 16
TROUBLSHOOTING
APRIL 2021
32DFR108.C
FR2SS-SERIES SERVICE MANUAL
Disconnect deploy
sensor connector P3
and pump wiring
harness connector P4
from controller.
Reconnect connector
P1 to controller. Set
STOW/DEPLOY switch
to DEPLOY.
Does circuit
breaker trip?
Yes
No
Defective controller.
Reconnect
connector P3 to
controller. Set
STOW/DEPLOY
switch to
DEPLOY.
J
From page 4-14
Does circuit
breaker trip?
Yes
Defective or damaged
deploy sensor.
No
K
To page 4-16