7
EN
PRIOR TO FIRST USE
1.
clean before first use.
Lid, racks, chamber, and accessories:
dishwasher safe, or
clean with soapy warm water before first use.
Electronic Base Unit:
Wipe clean only.
WARNING:
Never immerse the electrical base unit in water.
2.
Pour 100ml of water onto the stainless steel heating plate.
(i)
3.
Place the bottle chamber on the sterilizer base. Next, place the
bottle, plate and accessories rack inside the bottle chamber.
close the lid.
(ii)
4.
Press sterilize cycle on the control panel. this will take 15
minutes. after the cycle is done, you will hear 3 beeping sounds.
let it cool for 15 minutes before first use.
(iii)
LET’S GET STARTED
1.
all items intended for sterilization must be washed clean,
completely rinsed with fresh water and drained.
IMPORTANT:
all items must be able to withstand boiling conditions in
order to be sterilized and dried in this unit. (100°c or 212°F)
2.
remove the bottle chamber from the base unit. Use the
measuring cup included in the package to pour exactly 100ml of
fresh cold water onto the heating plate. more or less than 100ml
may not sterilize the items properly.
IMPORTANT:
excess amount of water on the heating plate may flow
into the air vent causing the electronic base unit to fail. Please note
that our warranty does not cover this type of user error.
TIP:
Hard water may increase mineral buildup on the heating plate.
We recommend using filtered water if you live an area with hard water.
(i)
(ii)
(iii)