27
MOBILE TEST BENCH
4.3 Function
Fig. circuit diagram
The mobile test bench is divided into four areas. These can be described as
follows:
Area C ‘Supply’
Area C, ‘Supply’, is responsible for the compressed-air supply of the mobile
test bench via the compressed-air system of the workshop.
– For this purpose, connect the coupling of the blue supply hose to the barb
nipple P
in
on the mobile test bench.
– Make sure that the S8 switch cock is in zero position.
– Now connect the blue supply hose to the compressed-air system on site.
– Use the precision control valve V8 to adjust the pressure to the intended
level for the subsequent test procedure.
– Once the pressure has been adjusted to the desired level you can open
switch cock S8.
The pressure thus set is now applied to the three independent
circuits in the ‘Control’ area.
Area A ‘Control’
The ‘Control’ area is responsible for the pneumatic actuation of the
specimen. Three independent circuits, to which three pressure gauges
(G1 - G3), three switch cocks (S1 - S3) and three compressed-air outlets
(C1 - C3) are respectively assigned, are available for this purpose.
– First, connect a compressed-air hose (C1 - C3) to a compressed-air
outlet.
en
Summary of Contents for MOBILE TEST BENCH 453 197 003 0
Page 2: ......
Page 106: ...104 MOBILE TEST BENCH 1 2 3 ru...
Page 107: ...105 MOBILE TEST BENCH WABCO 4 4 1 ru...
Page 109: ...107 MOBILE TEST BENCH S1 S9 Pin 7 2 4 3 Pin S8 V8 ru...
Page 113: ...111 MOBILE TEST BENCH 7 7 1 Pin 6 8 8 1 Pin 9 V8 5 G8 ru...
Page 126: ...124 MOBILE TEST BENCH 1 2 3 zh...
Page 129: ...127 MOBILE TEST BENCH 4 3 C C Pin S8 V8 S8 A G1 G3 S1 S3 C1 C3 C1 C3 S1 S3 zh...
Page 132: ...130 MOBILE TEST BENCH 7 7 1 Pin 6 8 8 1 Pin C9 V8 G8 5 bar S8 S9 C9 8 2 zh...
Page 134: ...132 MOBILE TEST BENCH...
Page 135: ......