19
Hardware Trigger Function
Hardware trigger mode is available only when the camera works at slave mode, in slave mode
the camera will wait for the hardware trigger signal on Ext_Trigger.
The EXT_Trigger signal is to driver the MOSFET, External input trigger signal voltage should
range 3.3V-20V, driving current ability should be more than 5mA;
You can use input pin Ext_Trigger to send a hardware trigger signal to the camera. The
hardware trigger can be used to trigger the acquisition start.
A hardware debouncer circuit
shall be considered on the EXT_Trigger line.
By default, the hardware trigger is
rising edge
activated, refer to below exposure timing:
T1
Frame start
EXT_Trigger
Camera Exposure
T1
Frame start
T2
T3
The requirement to T1 should be from 100us to 2ms;
T2 means the interval between two trigger signals, it MUST be more than 33ms;
T3 means the exposure time of the frame, it varies according to the range mode;