3.2
Electrical Specifications
3.2.1 Recommended Operating Conditions
Parameter
Symbol
Conditions Min
Typ.
Max Units
DC Power
VDD
11
12
26
V
Digital I/O
(Exposure_timing)
Vout
Work
mode
5
V
Digital I/O
(Ext_Trigger)
Vin
3.3
20
V
RS485
-12
12
V
Operating Temperature
Ta
-20
50
°C
Operating humidity
20
80
%
Storage humidity
20
80
%
Storage temperature
-30
70
°C
3.2.2 Power Consumption
Parameter
Conditions
Average
Max
Units
Range 0
350mm-1200mm @30fps
278
369
mA
Range 1
500mm-2800mm@30fps
413
587
mA
Range 2
800mm-4400mm@30fps
481
698
mA
Range 5
1200mm-6000mm@15fps
532
1233
mA
Note: 12V input voltage
3.2.3 Absolute Maximum Ratings
This
is a stress rating only and functional operation of the devices at those or any other
conditions above those indicated in the operation
listings of this specification is not
promised. Exposure to maximum rating conditions for extended periods may affect
device reliability
Parameter
Symbol Conditions
Min
Typ.
Max Units
DC Power
VDD
9
12
30
V
Digital I/O
(Ext_Trigger)
Vin
-0.3
20
V
RS485
-13.2
13.2 V
Operating Temperature
Ta
-20
50
°C
Summary of Contents for DCAM560C