System Configuration

Installation

Model: S1

Built-in box

Screws

Model: S2

Size: 261.7

*

175.3

*

15mm

Built-in box

Screws

Size: 205

*

126

*

15mm

Summary of Contents for S2

Page 1: ...Indoor Monitor Operation Manual For TCP IP with VYROX V90 V91 system ...

Page 2: ...bt please call our tech supporting and customer center Our company applies ourselves to reformation and innovation of our products No extra informing for any change The illustration shown here only used for reference if there is any difference please take the actual product as standard product ...

Page 3: ...Parameters 1 Product Pictures 2 Operations 4 1 VOIP 5 2 3 VHome iSmart 16 4 VHome PRO iCloud 20 Security 12 5 About V90 V91 21 Web Settings 22 System Configuration 25 System Diagram 26 Installation 28 Troubleshooting 30 Safety Precaution 31 ...

Page 4: ...me PRO iCloud support community information and website Contacts support android address book 2 Operating system Android 4 2 2 1 Technology Parameters Voltage DC 12V Rated power 6W Standby power consumption 1 5W Display screen 7 10 2 Resolution 800 480 1024 600 Operating temperature 10 50 Relative huminity 20 85 CPU single core 1GHz multi core 1GHz Memory DDR3 512MB single core DDR3 1GB multi core...

Page 5: ...Apply for V91 system Power Volume Return Speaker TF card slot USB interface Microphone Camera Display screen Model S2 Apply for V90 V91 system Power Return Speaker Camera Display screen TF card slot USB interface Microphone ...

Page 6: ...Model S3 Apply for V90 V91 system Power Return Speaker Camera TF card slot USB interface Model S4 Apply for V90 V91 system Power Return Speaker Camera TF card slot USB interface Microphone 3 ...

Page 7: ...n click it to return to previous menu click it to return to main interface Volume 6 Volume 7 C 2 Main interface 3 Background program Click it to display the operating program on the background 4 Screenshot click it to make the screenshot for V91 system 5 Click it to reduce the volume Click it to increase the volume System setup lick it to enter into the system setup menu 8 Time set it in the syste...

Page 8: ...owing interface 1 1 Call Click Call icon the system will enter the following interface 1 VOIP 1 1 1 Call unit resident Input 1 3 digit building No Building 2 digit Unit No Door 4 digit room No then click icon to call The system will enter into the following interface 5 ...

Page 9: ...o end the call click icon to unlock the door Remark visual intercom function between households is optional You can make audio and video recording during communication TF card should be inserted into indoor monitor Click icon to snapshot the visitor s image click icon to save the video and image for the current communication 1 1 2 Call management center Click Center icon to call management center ...

Page 10: ...to end the monitor Click icon to unlock the door Remark if exceeds 30 seconds it will exit monitor 1 3 Records Click Records icon the system will enter the following interface refers to call out record refers to call in record refers to missed call record Click or icon to search records Select one record and click icon to call click icon to delete it If has snapshot image click icon to view it ...

Page 11: ...Room No Device No and Synchronous No is the same as Building No setting The Unit No Floor No and Room No is limited 2 digits respectively Device Device When No is set to be 0 we regard the indoor monitor as the main when No is set from 1 to 5 we regard it as the sub1 to sub5 Click icon on top right corner to make network setup the system will enter into the following interface 1 4 Room Click Room ...

Page 12: ...erface Click Advanced Configure icon to enter into the following interface IP address is unique The default Mask address is 255 255 255 0 Normally it is unnecessary to modify Wi Fi function is reserved Click More icon to enter into the following interface ...

Page 13: ...tting without any change Click OK to save the setting Remark the setting should be made after inputting password to enter into room No setting 1 5 VOIP Click VOIP icon the system will enter the following interface Proxy sip proxy server URL the form is sip ip or sip realm name Realm the scope for the device is the same with IP or realm name Password the password switched in proxy server offered by...

Page 14: ... click OK icon 1 6 2 Password Click Password icon to enter into the following interface You can set the new system password with 1 16 digits the default password is 123456 System password is used for system settings 1 6 Settings Click Settings icon the system will enter the following interface ...

Page 15: ......

Page 16: ...FF 1 During the alarm delay time Click OFF icon the system will sound a tone then the alarm is stopped 2 Input user password the default password is 1234 to stop the alarm under alarm ON status 2 2 Zone Remark the setting should be made when alarm OFF Click Zone icon input 1 16 digits password the default password is 1234 the system will enter into the following interface ...

Page 17: ...e the alarm sensor is triggered 5 seconds later the indoor monitor will sound sirens 2 2 1 Alarm Type Click type input box it will popup a dialog box as the following In this interface you can set alarm Type as Normal Emergency and 24H 24H and Emergency type are always active 2 2 3 Sensor Type Click sensor type input box it will popup a dialog box such as the following interface Each sensor type c...

Page 18: ... management center if your system installed management center You can see the No and sensor type in red color showed at the top of interface For example 2 Smoke To stop the alarm sound input the password the default password is 1234 to indicate that Zone 2 Smoke sensor are triggered 2 3 Scene Click Scene icon the system will enter into the following interface ...

Page 19: ...station with icon 2 4 Settings Click Settings icon the system will enter into the following interface You can set the new user password with 1 16 digits the default password is 1234 User password is used for security Click iSmart icon on the main interface the system will enter into the following interface 3 iSmart ...

Page 20: ...3 1 Scene Click Scene icon the system will enter into the following interface Scene mode includes Home Out Movie Party and sleep 3 2 Light Click Light icon the system will enter into the following interface ...

Page 21: ...will enter into the following interface Set the air condition switch of corresponding room Click icon to turn air condition on off click icon to cool click icon to dehumidify click icon to ventilate 2 air conditions can be set every room at most OFF Cold Wet Wind 3 4 Curtain Click Curtain icon the system will enter into the following interface Click icon the curtain is closed if click icon the cur...

Page 22: ...ur system must connect with Elevator Control module Kindly check with your system provider 3 6 Settings Click Settings icon the system will enter into the following interface 3 6 1 Room setting You can add delete room data and change the room type The room types includes Living Dining Master Sub Study Kitchen and corridor There are max 20 rooms you can set 3 6 2 Light setting Click LIGHT icon the ...

Page 23: ...ponding room s lamp Choose the room type firstly then you can set the name for each light Click iCloud icon on the main interface the system will enter into the following interface 4 iCloud 4 1 SMS Click SMS icon the system will enter into the following interface BROWSER ...

Page 24: ... delete the record 64 records can be received in SMS at most 4 2 BROWSER Click BROWSER icon the system will enter into the web page linked with the indoor monitor the function should be supported by outer network COOK MAP GOV and MALL is reserved 5 About V90 V91 Click About V90 V91 icon on the main interface the system will enter into the following interface You can look over the relevant informat...

Page 25: ... s IP address in the browser then input user name and password the default user name is admin the password is 123456 to enter into the web setting interface 1 VOIP Click VOIP icon to enter into the following interface The setting is same with indoor monitor s If want to connect with SIP phone check SIP Enable and input the number registered in SIP server Timeout choose the longest communication ti...

Page 26: ...to answer when outdoor panel calls it and no answer within 10s Remark the address can be the SIP address of indoor monitor or other factory s VOIP device Click Quick Call Input SIP address of the specified management center it can be indoor monitor also be other IP phone the format can be like this sip user name SIP server IP address When click center icon it will be transferred to the binding equ...

Page 27: ...on it will logout the system Advertising used web page as the image Check the frame it will display Browser input the linking address in the frame and there is a BROWSER when the indoor monitor is on standby state icon on the indoor monitor when the user click the icon it will switch into the linking web page ...

Page 28: ...ic Lock 220V Terminal Power Network Switch 220V Terminal Power Network Switch Fiber Optical Transceiver Outdoor Panel Power Electric Lock Villa District Flat Camera Electric Lock 220V Terminal Power Network Switch Fiber Optical Transceiver Outdoor equipment box Flat Camera Electric Lock Terminal Power Indoor equipment box Indoor equipment box Network Switch Four core single mode fiber Four core si...

Page 29: ... 2 1 2 3 4 5 9 6 10 7 8 12V GND AL1 AL2 AL3 AL4 AL5 AL6 AL7 AL8 Siren Alarm 1 Power DC 12V 12V GND 485 485 RS485 Interface 12V GND 485 485 Power input interface connect with 12V power adapter 2 RS485 Connect with smart home alarm extern module etc Offer a group of 12V 100mA power by RS485 RS485 Equipment ...

Page 30: ...tates connect with normally open or normally closed switch Offer a group of 12V 100mA power by alarm interface Normally open sensor Normally closed sensor 4 RJ45 Connect with outdoor panel indoor monitor or other network equipment by network switch 5 Siren When alarm sensor is triggered output 12V mA power Siren Alarm facility ...

Page 31: ... 28 System Configuration Installation Model S1 Built in box Screws Model S2 Size 261 7 175 3 15mm Built in box Screws Size 205 126 15mm ...

Page 32: ...Model S3 Size 270 168 15mm Built in box Screws Model S4 Size 205 129 15mm Built in box Screws 29 ...

Page 33: ...usted at the minium The indoor monitor cannot monitor the outdoor panel Other users is using the system when he finished the use you can use it normally Multimedia files cannot be played normally Check whether the system supports the file format please refer to multimedia setting for details Touchscreen responses slowly or cannot make calibnation Take down any protective paster it may affect ident...

Page 34: ...e Don t install the device on the rocking and vibrant place to avoid the device s falling to cause property loss or personnel injury Prevent electric shock fire and explosion Don t use damaged power line plug or loosen outlet Don t touch the power line with wet hand or pull the power line Don t buckle or damage the power line Don t touch the device with wet hand Don t make the power supply fell or...

Page 35: ...re attention when stand up Don t disassemble configure or fix the device by oneself the manufacturer will not guarantee for any change or configuration of device If need to repair please contact with customer service center If the device makes strange sound taste or smoke please unplug the power supply immediately and contact with customer service center in time If not use the device for long time...