12
Press the ‘ENTER’ button, now you can scroll the eight sampling volume. The selectable volumes are 10, 20, 30, 50,
100, 200, 500, 1000 litres).
S.PROG XXXX
MM/DD/YY - HH:MM
Once the desired sampling volume has been reached press the ‘ENTER’ button to confirm. The instrument is now
ready to sample the selected volume of air. Press the ‘START’ button to begin the sampling cycle
START FOR XXX
MM/DD/YY - HH:MM
‘USER MODE’
If the operator wish to use volumes other than the standards volumes, up to 8 additional volumes can be
programmed into the unit.
The user-selectable volumes can be selected from the USER MODE, while the selectable volumes can be modified
using the PROGRAM MODE function describe in the next paragraph. Switch on the instrument and wait until the
main screen is displayed:
START FOR XXX
MM/DD/YY - HH:MM
Press the “
▼
” or “
▲
” arrows to reach the
USER MODE
MM/DD/YY - HH:MM
Press the ‘ENTER’ button, now you can scroll the eight user-defined sampling volumes.
S.PROG XXXX
MM/DD/YY - HH:MM
Once the desired sampling volume has been reached press the ‘ENTER’ button to confirm. The instrument is now
ready to sample the selected volume of air. Press the ‘START’ button to begin the sampling cycle
START FOR XXX
MM/DD/YY - HH:MM
The total number of available ‘USER MODE’ programmes is eight. The maximum volume of air for each sampling
cycle is 1999 litres.
‘PROGRAM MODE’
Using this procedure, it is possible to memorise up to eight different volumes (from 1 to 1999 litres of air).
(See chapter 4.4.).
ENGLISH