background image

Maintenance

Explosion-Proof & FMS Refrigerator-Freezers

Installation and Operation Manual

         17

Order From Your VWR Sales Office

ALBUQUERQUE

3455 Princeton Dr. NE

Albuquerque, NM 87105

505/883-8726

DALLAS

PO BOX: 152643

Irving, TX 75015

1-800/932-5000

KANSAS CITY

PO BOX: 66929

O’Hare AMF

Chicago, IL 60666

1-800/932-5000

PHILADELPHIA

PO BOX: 626

Bridgeport, NJ 08014

1-800/257-8407

ST. LOUIS

PO BOX: 66929

O’Hare AMF

Chicago, IL 60666

1-800/932-5000

ANCHORAGE

5401 Fairbanks Street

Anchorage, AK 99518

907/563-4070

DENVER

PO BOX: 39396

Denver, CO 
80239

303/371-0970

LOS ALAMOS

PO BOX: 131

Los Alamos, NM

87544

505/662-5558

PHOENIX

PO BOX: 29027

Phoenix, AZ 85038

602/269-7511

SALT LAKE CITY

PO BOX: 25534

Salt Lake City, UT

84125

801/972-6400

ATLANTA

PO BOX: 13007

Atlanta, GA 30376

1-800/241-5450

DETROIT

PO BOX: 66929

O’Hare AMF

Chicago, IL 
60666

1-800/932-5000

LOS ANGELES

PO BOX: 6016

Cerritos, CA 90702

213/404-0770

PITTSBURGH

PO BOX: 626

Bridgeport, NJ 08014

1-800/257-8407

SAN DIEGO

PO BOX: 85462

San Diego, CA 

92138

1-800/423-5559

BALTIMORE

PO BOX: 626

Bridgeport, NJ 08014

1-800/257-8407

HONOLULU

PO BOX: 29697

Honolulu, HI 
96820

808/836-1361

MIAMI

PO BOX: 520127

Miami, FL 33152

1-800/241-5450

RALEIGH/DURHAM

PO BOX: 12253

Research Triangle 
Park

NC 27709

1-800/241-5450

SAN FRANCISCO

PO BOX: 7900

San Francisco, CA

94120

415/467-6202

BOSTON

PO BOX: 232

Boston, MA 02101

617/461-1880

HOUSTON

PO BOX: 330348

Houston, TX 
77233

713/641-0681

1-800/392-3338

o/s TEXAS:

1-800/527-1576

MINNEAPOLIS

PO BOX: 66929

O’Hare AMF

Chicago, IL 60666

1-800/932-5000

ROCHESTER

PO BOX: 1050

Rochester, NY 14603

716/247-0610

SEATTLE

PO BOX: 3551

Seattle , WA 
98124

206/575-1500

CHICAGO

PO BOX: 66929

O’Hare AMF

Chicago, IL 60666

1-800/932-5000

INTEGRATED 
SUPPLIER

609/467-2600

NEW ORLEANS

5717 Saimen Street

Harahan, LA 70123

1-800/527-8030

NEW YORK CITY

CN 1380

Piscataway, NJ 
08854

201/756-8030

VWR FURNITURE DEPARTMENT

PO BOX: 3405

Irving, TX 75062

3041 Skyway Circle N.

214/258-6953

INTERNATIONAL

PO BOX: 7900

San Francisco, CA

94120 USA

415/468-7150

TELEX:

7607279 VWR UC

278778 VWR UR

PO BOX: 7900

SAN FRANCISCO, 
CA 94120

415/468-7150

Summary of Contents for 47747-222

Page 1: ...2015 All rights reserved Printed in U S A VWR Scientific Brand Explosion Proof and Flammable Materials Storage Refrigerator Freezers Installation and Operation Manual MODEL NO 47747 222 47747 224 477...

Page 2: ...Clearance 8 Electrical 8 Be Advised 9 How to Seal Killark Box Conduit with Fiber and Sealing Compound to Help Protect Against Explosions Explosion Proof Units Only 10 Operation 13 Start Up Procedure 1...

Page 3: ...n this apparatus is not designed for use in Class I II or III locations as defined by the US National Electrical Code unless otherwise noted Alert Signals ON OFF Safety Alert Important operating instr...

Page 4: ...ER RISK OF CHILD ENTRAPMENT Before you throw away your old refrigerator or freezer Take off doors Leave the shelves in the place so that children may not easily climb inside If the equipment is used i...

Page 5: ...sion Proof Care in storage is still required Store only corrosive reagents samples which truly need reduced temperature storage Flammable corrosive materials require Flammable Material Storage or Expl...

Page 6: ...ll remain below the flashpoint of any flammable material likely to be found in Class I Groups C and D Class I Zone 1 and Group IIB locations All models have heavy gauge rigid braced steel construction...

Page 7: ...oltage and current spikes which could cause a spark resulting in a fire or explosion It is the end users responsibility to meet these requirements VWR cannot assist with the selection of devices recom...

Page 8: ...of hazardous materials inside the unit They are NOT designed for use in Class I Groups C and D environments for these locations use a VWR Scientific Explosion Proof Refrigerator However FMS units are...

Page 9: ...could cause a spark resulting in a fire or explosion It is the end users responsibility to meet these requirements VWR cannot assist with the selection of devices recommend approve or design any devic...

Page 10: ...certain that all parts are accounted for before packaging materials are discarded After unpacking if damage is found promptly report it to the carrier and request a damage inspection promptly IMPORTAN...

Page 11: ...TION BEFORE CONNECTING THE FINAL POWER SUPPLY CHECK THE ELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT IS IN AGREEMENT WITH THE POWER SUPPLIED IN ADDITION POWER SHOULD BE WIRED TO THE...

Page 12: ...n the two and forms into an airtight plug All of this is done in order to prevent the very real threat of gas entering the Killark box and a resulting serious explosion After the unit wires have been...

Page 13: ...he left hub and most importantly being sure the material COMPLETELY SURROUNDS THE WIRING from the top to the bottom completely blocking this end of the horizontal conduit Insert fiber rope material do...

Page 14: ...the remaining space Pour slowly being careful not to trap air bubbles Immediately wipe off any spilled sealing compound Screw conduit domed cover back onto conduit opening NOTE INITIAL SETUP OF SEALI...

Page 15: ...tabilizes allow 1 2 to 1 hour for the chamber temperature to stabilize after subsequent temperature adjustments Because the markings on the dial do not indicate specific temperatures use them AS REFER...

Page 16: ...buildup Set operating temperature no colder than necessary for the items being refrigerated Safety Tips After a unit is in operation do not touch the cold surfaces particularly when hands are damp Ski...

Page 17: ...dry brush or vacuum A leak around the door gasket will allow cold air to escape This causes unit to work harder than necessary to maintain cold temperatures Re seat or replace the gasket if worn If yo...

Page 18: ...ective gloves to prevent frostbite especially when removing items from freezer units 4 Do not use abrasive scouring powders waxes solvents furniture polish undiluted detergents or cleansers containing...

Page 19: ...4 1 800 257 8407 SAN DIEGO PO BOX 85462 San Diego CA 92138 1 800 423 5559 BALTIMORE PO BOX 626 Bridgeport NJ 08014 1 800 257 8407 HONOLULU PO BOX 29697 Honolulu HI 96820 808 836 1361 MIAMI PO BOX 5201...

Page 20: ...n Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE marcato col s...

Page 21: ...d International Warranty 16 Month Parts Warranty VWR In warrants this product to the owner for a period of sixteen 16 months from the date of shipment by VWR If any part is found to contain a manufact...

Page 22: ...057 658 00 Rev B...

Reviews: