Summary of Contents for Pool Heater

Page 1: ...VULCAN Pool Heater Installation Operating Manual...

Page 2: ...England to the highest standards To ensure your new heater will give years of trouble free service please carefully read the following instructions Incorrect installation will affect your warranty Do...

Page 3: ...stalled at a low point in the filtration system It should be positioned downstream after of the filter and upstream before of any dosing or other water treatment plant see fig 3 NOTE If the flow direc...

Page 4: ...3 ENGLISH Flow switch at top For vertical wall mounting water must always enter at the bottom Fig 3 Fig 4 PUMP FILTER POOL VULCAN HEATER NON RETURN VALVE WATER TREATMENT...

Page 5: ...er is not used during winter months it must be drained to prevent frost damage Electrical Connection The heater must be installed in accordance with the country regional requirements regulations In an...

Page 6: ...en rotated it is important to ensure that it is finally locked in the correct orientation perpendicular at right angles to the flow of water Power Output Voltage V Amp 3 kW 230 13 4 5 kW 230 20 6 kW 2...

Page 7: ...l Dissolved Solids Calcium hardness 200 1 000ppm Water chemistry is complicated if in doubt seek expert advise Operating Your Heater Upon completion of the installation run the water circulating pump...

Page 8: ...nt temperature To display modify the required temperature press and release the P button The pre programmed required temperature will be displayed Press 3 to increase or 2 to decrease the required tem...

Page 9: ...h tem perature alarm display This alarm is shown as HI flashing within the temperature display window This alarm is activated if the water temperature is 2 C or more above the required temperature As...

Page 10: ...output two electricity meter readings will need to be taken from the properties main electricity meter with an exact one hour interval ie take one meter reading and then a second reading exactly one...

Page 11: ...button to re set see fig 8 If a positive click is felt the cause of the tripping must be investigated and could be caused by a debris build up or air pocket trapped inside the flow tube of the heater...

Page 12: ...if not illuminated raise the required temperature to a value higher than the current water tempera ture Confirm whether the heater now switches to Heat on mode red light Possible cause 2 The high limi...

Page 13: ...trapped inside the heater particularly if the tank feels warmer at the highest point of the tank as air rises THE WATER ENTERING MY POOL DOES NOT FEEL MUCH WARMER The temperature gain of the water aft...

Page 14: ...his product should not be treated as household waste Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this produ...

Page 15: ...ses of incorrect installation of the heater inapropriate use or neglect of the heater CE Declaration Of Conformity The manufacturer declares that the herewith products or ranges ELECTRIC SWIMMING POOL...

Page 16: ...90...

Page 17: ...91...

Page 18: ...11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH United Kingdom t 44 0 1438 749 474 f 44 0 1438 361 329 e info elecro co uk Copyright 2011 Z INS VULC EVO...