21
EXAMPLE PROGRAM
This example shows how to program a three-phase process for cooking Roast Beef, 18 pounds per
roast, and store it as program number 20.
The second item in the table on page 17 provides most of the information: For Combi time, Phase 2,
15 minutes-per-pound times 18 pounds-per-roast yields 270 minutes. We assumed that 20% Steam
Time would be OK. We chose the average temperature when a temperature range was given. In this
example, we will not use the temperature probe.
Phase 1
Phase 2
Phase 3
STEAM Mode
212 °F
20 minutes
COMBI Mode - 20% Steam Time
295 °F
4 hours and 30 minutes
CONVECTION (HOT AIR Mode)
375 °F
10 minutes
Turn the oven ON.
Phase 1
Select Steam Mode by pressing
. The first light blinks on the phase button
to
indicate you are programming Phase 1. Press
: The Temperature displays 212
°
F
and needs no adjustment. Press
and press
to increase or
to decrease
until the Time displays [ –
h
20
min
]. Press
to shift to Phase 2: The second indicator
light begins to flash.
Phase 2
Select Combi Mode - 20% Steam Time by pressing
once. The first indicator
light will be lit indicating 20% Steam Time. Press
and press
to increase
or
to decrease until the Temperature displays 295
°
F. Press
and press
to
increase or
to decrease until the Time displays [ 4
h
30
min
]. Press
to shift
to Phase 3: The third indicator light begins to flash.
Phase 3
Select Convection
(HOT AIR)
Mode by pressing
. Press
and press
to
increase or
to decrease until the Temperature displays 375
°
F. Press
and
press
to increase or
to decrease until the Time displays [ –
h
10
min
]. Press
twice.
Save
Press the
key and press
to increase or
to decrease until the Program
Number displays
. Verify that this program number is vacant, or choose a different
program number that is vacant. A vacant program displays the current temperature, blank
Time [ –
h
– –
min
], and no Mode or Phase indicator lights are lit. Then press
until
the program number stops being displayed, indicating the program is saved in memory.