– 21 –
PL-40052
Standard Oven Pilot
Before lighting oven, be sure that range top sections have been lit.
1.
Open oven door and locate square pilot lighter cutout.
2.
Using a taper, light oven pilot by depressing red ignition button (Fig.19) located on the side
control panel above the thermostat knob. Light the pilot and continue to hold the ignition button
in for one minute. If pilot fails to light, turn main gas valve OFF and wait 5 minutes before repeating
Steps 1 and 2.
3.
Set oven thermostat to desired temperature.
Fig. 19
Nightly Shutdown: Turn oven burner valve OFF.
Complete Shutdown: Turn oven burner valve OFF. Turn main gas supply OFF.
Convection Oven Pilot
Before lighting oven, be sure that range top sections have been lit.
1.
Connect range to the main electrical supply line. Open oven door panel and locate square pilot
lighter cutout.
2.
Turn red gas valve (located behind the control panel) ON, purging the gas line of all air. Turn gas
valve and power switch OFF. Close oven door.
3.
Light oven pilot by depressing the red ignition button (see Fig. 19), and using a taper, ignite the
pilot. Hold ignition button in for 30 seconds, or until pilot remains lit. Turn gas valve back ON.