5.
The griddle plate is packaged separately from the range. Inspect bottom of griddle plate and
ensure that the thermostat sensor holding bracket and hardware are attached. Loosen hardware
so that plate is easily moved and tilts downward.
On the top burner box front area of the range, find the coiled thermostat capillary and bulb
assembly (Fig. 16). Gently uncoil the capillary. Lift (two people required) the griddle plate onto
the range top, being careful not to crush the thermo bulb. Wedge a 2x4 under the front part of
the griddle to hold the plate up. This is necessary in order to install the thermostat bulb to the
holding bracket.
Fig. 16
Slip the thermostat bulb into the v-slot in the bracket (Fig. 17) and tighten down the bracket
hardware securely. Feed capillary coil neatly under plate to make sure it will not be crushed when
plate is lowered into place. Remove the 2x4 and gently lower griddle plate down into place. Make
sure plate is resting evenly on the range top.
Fig. 17
PL-41478-1
THERMO BULB
CAPILLARY COIL
PL-41479-1
V-SLOT
BRACKET