CONTROLS   

Dual Zone Controls  

 

Controls  cooking  areas  in  the  left  and  right  hand  side  of  the  cavit y 
allowing for flexibilit y and prem ium  cooking perform ance . 

Angled Handle 

  e

levates  or  lowers  the  broiling  grid  to  different  positions.    Grasp  the 

handle  and  pull  towards  broiler  cavit y.    This  releases  the  m echanism 
and allows the lifting handle to m ove into  the desired position.  

Burner Valve

 

—  regulates  the  flow  of  gas  to  the  burners.    Gas  flow  is  increased  by 

turning the valve counterclockwise.  

Drip Tray

 

—  Collects grease and waste which is diverted by the tilt of the drip shield.  

DO NOT allow  the drip tra y to overf low.  Em pt y the  drip tra y  when three -
quarters full to reduce the possibilit y of spillage.  

Rack Handle 

—  glides the  grid forward for easy  loading and unloading.  To operate, pull 

straight out.    

LIGHTING, RELIGHTING AND SHUTDOWN INSTRUCTIONS 

1.  Turn burner valve to the OFF position and wait 5 minutes.  

2.  Light  the  pilot  adjacent  to  the  main  burner.  Adjust  the  pilot  valve  screw  until  the  pilot 

flame  has  a  slight  yellow  tip.   There  are  two  pilots  to  light,  on  each  end  of  the  cooking 
chamber.  

3. 

After  the  pilot  has  been  established,  turn  the  burner  valve  to  the  ON  position.    The 
burner  flames  may  be  adjusted,  using  the  air  shutters  located  behind  the   manifold 
cover in the front of the range.  There are no shutters on the IRB models.

 

4.

 

If the burners fail to light,  turn off all valves, wait 5 minutes and repeat steps 1 -3. 

5.

 

To shut down, turn the burner valves to the OFF position.  

RACK POSITION AND GAS SETTING 

Each  operator  will  find  the  optimum  rack  position  and  gas  setting  for  various  products; 
however, it is recommended that gas input be reduced first when lower rack temperatures 
are  desired.    Further  reduction  in  rack  temperatures,  if  necessary,  can  then  be  obtained 
by  lowering  rack  position.  Infrared  Models  must  use  the  full  gas  setting.   Max  and 
minimum temperatures can be achieved at the following settings:  

2 Burners On, rack at highest position, valves set to High 

– 800°F 

1 Burner On, rack at lowest position, valves set to Low 

– 250°F 

CLEANING 

  1.  Allow broiler to cool.  

  2.  To remove broiler rack for cleaning, adjust broiler rack to center position.  

Summary of Contents for 36IRB

Page 1: ...Westlake Dr Charlotte NC 28273 RETAIN THIS MANUAL FOR FUTURE USE FORM F 47200 10 13 INSTALLATION OPERATION MANUAL FOR Salamander Broilers MODELS 36RB 36IRB www vulcanequipment com MODELS C36RB C36IRB...

Page 2: ...ORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLA...

Page 3: ...titude Kits Accessory Number Description ALTISR N01 KIT RB ALTITUDE NG SEA 1999FT ALTISR P02 KIT RB ALTITUDE LP SEA 1999FT ALTISR N03 KIT RB ALTITUDE NG 2000 3999FT ALTISR P04 KIT RB ALTITUDE LP 2000...

Page 4: ...ocated underneath the broiler rack drip tray If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately UNPACKING Immediately after unpa...

Page 5: ...400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1 Batterymarch Park Quincy MA 02169 7471 NOTE In the Commonwealth of Massachusetts All gas appliances vented through a v...

Page 6: ...ould be fully purged to remove air GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column W C for natural gas and 10 W C for propane gas Minor adjustments may be requir...

Page 7: ...be needed to wall mount the unit 1 Follow the combustible noncombustible clearance guidelines that are listed in the Installation section in this manual 2 Make sure brackets are level and properly spa...

Page 8: ...8 Radiant Infrared Salamander shown on WALLMNT CHRBKR Accessory Fig 4 Fig 5 Fig 6...

Page 9: ...e 2 Using the four bolts provided install mounting brackets on both top corners of reinforced shelf 3 Place and align broiler on top of brackets with the back of the unit flush with the rear of the sh...

Page 10: ...screw until the pilot flame has a slight yellow tip There are two pilots to light on each end of the cooking chamber 3 After the pilot has been established turn the burner valve to the ON position The...

Page 11: ...r Rinse thoroughly and wipe dry with a soft clean cloth 11 Clean stainless steel surfaces with a mild detergent and water using a damp cloth or with a commercial stainless steel cleaner Rinse thorough...

Page 12: ...12 NOTES FORM F 47200 10 13 PRINTED IN THE U S A...

Page 13: ...12 NOTES FORM F 47200 10 13 PRINTED IN THE U S A...

Page 14: ...eau savonneuse Rincer fond et essuyer avec un chiffon doux et propre 11 Nettoyer les surfaces en acier inoxydable avec un d tergent doux et de l eau utilisant un chiffon humide ou un nettoyant commerc...

Page 15: ...la flamme soit jaune Il y a deux veilleuses allumer chaque bout de l enceinte de cuisson 3 Lorsque la veilleuse est r tablie mettre le robinet du br leur la position ON marche R gler les flammes du b...

Page 16: ...les quatre boulons fournis et installer les supports de montage sur les deux coins sup rieurs de la tablette renforc e 3 Placer et aligner le grilloir sur le dessus des supports le dos de l appareil g...

Page 17: ...8 Salamandre radiant et infrarouge illustr e dans l accessoire WSALLMNT CHRBKR Fig 4 Fig 5 Fig 6...

Page 18: ...Quincy MA 02269 ASSEMBLAGE Salamandre grilloir mont e sur un mur Fig 4 L accessoire de support de montage du mur s par WALLMNT CHRBKR sera requis pour monter l appareil au mur 1 Suivre les directives...

Page 19: ...INSTALLATION D UN R GULATEUR DE PRESSION DE GAZ Le r gulateur de pression de gaz est pr r gl en usine une pression de 1 25 kPa 5 po de colonne d eau pour le gaz naturel et de 2 49 ka 10 po de colonne...

Page 20: ...Batterymarch Park Quincy MA 02169 7471 NOTA Dans le Commonwealth ou l tat du Massachusetts Tous les appareils au gaz ventil s par une hotte de ventilation ou un syst me d vacuation muni d un registre...

Page 21: ...MM DU NIVEAU DE LA MER INSTALLATION Avant de proc der l installation s assurer que le type de gaz naturel ou propane de l immeuble correspond aux sp cifications de la plaque signal tique plac e sous l...

Page 22: ...B GN 2 000 3 999 PI 6 097 12 189 MM DU NIVEAU DE LA MER ALTISR P04 JEU D ALTITUDE RB GPL 2 000 3 999 PI 6 097 12 189 MM DU NIVEAU DE LA MER ALTISR N05 JEU D ALTITUDE RB GN 4 000 6 999 PI 12 192 21 333...

Page 23: ...D ODEURS DE GAZ TEINDRE L APPAREIL PAR LE ROBINET D ARR T PRINCIPAL ET COMMUNIQUER AVEC LA COMPAGNIE DE GAZ LA PLUS PR S OU AVEC LE FOURNISSEUR DE GAZ ATTITR POUR L ENTRETIEN MESURE DE S CURIT NE PAS...

Page 24: ...SRL 10405 Westlake Dr Charlotte NC 28273 DOCUMENT CONSERVER EN CAS DE BESOIN F 47200 10 13 MODE D INSTALLATION ET MODE D EMPLOI Salamandres grilloirs MOD LES 36RB 36IRB www vulcanequipment com MOD LE...