SPECIFICATIONS

Table 2. Thermostat specifications.

Power

 

Power Supply

24 Vac nominal, 18-30 Vac, 50/60 HZ.

Electrical Rating
      

Heating rating

      Cooling rating
      Fan rating

Note: 

The fan load plus the higher of the heating or

cooling load must not exceed 1.5 Amp continuous

0.02 to 1.5 A continuous
0.02 to 1.5 A continuous
0.02 to 0.5 A continuous

TEMPERATURE  RATINGS

      Temperature setting range
      Ambient temperature range

 

Shipping temperature range

40 to 99 

°

F  (4 to 37 

°

C)

40 to 110

 

°

F (4 to 43 

°

C)

14 to 140 

°

F (-10 to 60 

°

C)

OPERATING RELATIVE HUMIDITY

5 to 90% RH, non-condensing

CYCLE RATES

     Cooling mode
     Heating mode

4  Cycles Per Hour
1,3,4,5,6,9,12  Selectable Cycles Per Hour

DIMENSION

Fig. 2.Thermostat dimension

Summary of Contents for TE80SB

Page 1: ...le 1 Description of Thermostat Model Mounting System Selection Fan Selection Powering Method Backlight TE80SB VERTICAL COOL OFF HEAT ON AUTO Power Stealing Backlight Fig 1 Thermostat FEATURES 7 Day pr...

Page 2: ...d 1 5 Amp continuous 0 02 to 1 5 A continuous 0 02 to 1 5 A continuous 0 02 to 0 5 A continuous TEMPERATURE RATINGS Temperature setting range Ambient temperature range Shipping temperature range 40 to...

Page 3: ...as indicated will result in poor temperature control NOTE Level thermostat mounting is for appearance only and is not required for proper thermostat operation Mounting Thermostat Take out the back pl...

Page 4: ...s used may result in the overheating of the electric heater elements due to improper fan operation The set up switch is an internal switch E F located near the wiring terminals It is used to select pr...

Page 5: ...the following steps to change each of the settings Each time you press key you will advance to the next operating parameter To go back you must re enter the installer set up as described above INSTALL...

Page 6: ...l or aggressive For aggressive the system will cool down the room to setting point faster than normal algorithm However an overshoot might be occurred in some situations a Press key to show the coolin...

Page 7: ...tarts and stop with heating equipment Minimum Off Timer For cooling when the thermostat calls for operation while the minimum off timer is not expired the star symbol keeps flashing Back Lighting The...

Page 8: ...e Note Default setting can be restored to memory by pressing HOLD and RUN buttons at the same time for 3 seconds Press or key to select desired programming period as below Press PROG to proceed The th...

Page 9: ...isappeared Set point will be updated to the programmed data Note that only the HOLD button can be used to exit the HOLD temperature CLOCK ADJUSTMENT The clock needs to be adjusted when installed The c...

Page 10: ...HEAT B terminal will get energized 2 Press key until the set point is higher than room temperature The star symbol is shown on the display The heating equipment is on and terminal W is energized 3 Pre...

Page 11: ...Note that resistor has to be installed at the fan terminals and not at thermostat terminals To install the Resistor 1 Disconnect power supply 2 Connect the resistor leads to the terminals as shown in...

Reviews: