Vtronix
11
Application Note
Attached 1000 ohm, 3 watt resistor is used in certain application to assure compatibility with power stealing
thermostats where Fan does not come ON during call for Heat or Cool. Note that resistor has to be installed
at the fan terminals and not at thermostat terminals.
To install the Resistor
1.
Disconnect power supply.
2.
Connect the resistor leads to the terminals
as shown in the drawing.
3.
Turn on the system power.
VTRONIX, LLC 318 Indian Trace #327, Weston, FL 33326
Copyright
©
2002 Vtronix Document no. 170306-500E Rev.00
Air Handler Fan Board
1000 Ohm
3Watt
Resistor
Thermostat
C
G
G