VTI Instruments Corp.
16
VM3608A/3616A Introduction
VM3608A/3616A
S
PECIFICATIONS
G
ENERAL
S
PECIFICATIONS
N
UMBER OF
C
HANNELS
VM3608A/3616A-1
VM3608A/3616A-2
VM3608A/3616A-3
16 channels
32 channels
48 channels
O
UTPUT
R
ANGES
±20.0 V, 610 µV step, or
±10.0 V, 305 µV step
O
UTPUT
C
URRENT
±50 mA per channel (1.5 A max., total for all channels per C-size VXIbus card)
R
ESOLUTION
16 bits, 16 bits monotonic
S
HORT CIRCUIT
Continuous duration
S
LEW
R
ATE
6 V/µs (50 mA load)
S
ETTLING
T
IME
10 µs to 0.1% of specified value
V
OLTAGE
A
CCURACY
*
10 V Range
20 V Range
3.22 mV
6.44 mV
C
ONVERSION
R
ATE
100,000 voltage changes/second, normal mode register access, FIFO mode, and ARB mode
100 voltage changes per second, normal mode word serial access
2,000 voltage changes per second, single VM3616A, scan mode
1,000 voltage changes per second, two VM3616As, scan mode
667 voltage changes per second, three VM3616As, scan mode
S
TATIC
M
ODE
U
PDATE
S
OURCES
VXIbus TTL trigger bus 0 - 7
Front panel input, TTL compatible
Updating any selected channel
Word serial command
M
EMORY
512 k words, 1 M word optional
FIFO
M
EMORY
512 k words divided by the number of active channels,
1 M word optional
FIFO
C
LOCK
S
OURCE
Any trigger source
ARB
(A
RBITRARY
W
AVE
F
ORM
)
M
EMORY
484 k words divided by the number of active channels, 996 k words optional
ARB
D
ATA
T
RACES
1 to 4096 unique patterns
ARB
S
EGMENTS
1 to 4096
ARB
L
OOP
C
OUNTER
1 to 1048575 or Continuous
ARB
A
DVANCE
M
ODES
Synchronous, waits for the end of the current pattern to advance to the next
Asynchronous, advances immediately to the next pattern upon being triggered