6 – PUTTING INTO OPERATION 

 
 

 

FILLING OF SWIMMING POOL 

Once again check connection of all pipes (see Section 3. "Installing and Connection") and start to fill the 

pool by water. Stop filling when the water reaches a level 

1 cm

 below the upper edge of the skimmer 

(see "Connecting to the water network). 

 

 

 

PLEASE OBSERVE THE FOLLOWING REQUIREMENTS AT THE TIME OF FILLING THE POOL: 

If the water does not meet the established standards (not clean enough), you can use for cleaning of 

water the filter bag, which is included in the complete set of filtration unit. To do this, insert the hose into 
the filter membrane fix the membrane on the hose and start to fill the pool. 

At the end of the swimming pool filling, rinse the membrane by water under pressure. 

 

 

 

ADJUSTING THE DEVICE OF AUTOMATIC WATER ADDING

 

To keep water in the pool always at one level (1 cm 

below the top of skimmer) necessary to adjust the screw 

of automatic water adding in filtration compartment.  

 

 
 

 

 

 

 

 

INITIAL START-UP 

Following the instructions from Section 4, "Safety and warnings", do the electrical connections.  

 

To remove air from the piping and pump, connect to the water supply flexible hose.  

WARNING 

Do not put the flexible hose in the discharge nozzle. Enough to keep the hose near the 

discharge nozzle. Stop filling pipelines by water when the air bubbles will stop. After filling the pipeline, 
make sure, that no leaks in the joints of pipes. Then fill the sand around the technical part and pipeline. 

Insert the filter membrane inside of filtration unit (see Section 7 "Filtration membrane). Turn on filter 

equipment and start primary cleaning of water in a manual mode. To do this, set the switch on the 

electrical control panel in "manual ". 

After two or three days of filtration unit in a manual mode, turn the switch on the electrical control panel 

in "automatic mode" and Install on a timer duration cycles of water filtration. 

 

  

 

TIMER SETTING 

You can use the timer of electrical control panel to set the daily filtration time of your pool. 

REMEMBER,

 the more often filtered swimming pool, the cheaper to maintain it!  Adapt the time of 

filtering to water temperature (time of filtering = temperature of water divided by 2). For example, if the 

temperature of water in your swimming pool = 24°

С

, then 24:2=12 hours (time which filtration unit must 

work). 

 

To set filtration time, it is necessary carefully to pull out the segments. One segment corresponds to 30 
minutes. To set timer’s clock, it is necessary to rotate dial face clockwise until a set time. It is forbidden 

to rotate a dial face counter-clockwise, it can damage it. 

 

 
 
 
 

Summary of Contents for Aquatic U

Page 1: ...INSTALLATION AND USER S GUIDE FILTRATION BLOCKS Aquatic U 15 m3 hour Equipment of high alloy steel for cleaning and filtering water in the pool...

Page 2: ...www vsv group com 2...

Page 3: ...14 Differential switch 14 Other security measures 14 5 ELECTRICAL CONNECTIONS 15 20 Electrical control panel 15 Wiring diagram of the electrical control panel 16 Connecting boxes 17 18 Electrical wir...

Page 4: ...t a sufficient distance from parts made from stainless steel to avoid getting chemicals on stainless steel equipment Otherwise on the surface of stainless steel can form rust and turbidity 3 Spread th...

Page 5: ...r standard filter membranes 6 15 microns front skimmer nozzle LED lights 2x10W 10000K the device of automatic water adding the suction pipe with pre filter grounding bolt Technical part includes one s...

Page 6: ...hout heating BLOCK Aquatic U 15 m3 hour Total assigned power of 0 47 kW with spotlights 2 10W one speed pump 0 45kW 50Hz performance capacity 15 m3 hour height H max 13 5 m The technical part without...

Page 7: ...for use with boilers Heat transfer 15 kW min 70 kW max BLOCK Aquatic U 15 m3 hour heat exchanger Total assigned power of 0 473 kW with spotlights 2 10W one speed pump 0 45kW 50Hz performance capacity...

Page 8: ...unit capacity 9 kW BLOCK Aquatic U 15 m3 hour electric heater Total assigned power of 0 47kW with spotlights 2 10W 9 47kW with electric heater 9 kW one speed pump 0 45kW 50Hz performance capacity 15...

Page 9: ...www vsv group com 9 2 DIMENSIONS OF EQUIPMENT...

Page 10: ...the block on the wall of the pool as shown below taking care not to damage the waterproofing coating liner If necessary align it with the water level and fasten the block mounting bolts in a projecte...

Page 11: ...by sand VENTILATION Warning Never cover the ventilation holes in the lid of the technical compartment Otherwise the equipment will have to work with increased productivity which increases power consu...

Page 12: ...ble for water supply in your area Adding of water Bring the pipe to filtration unit and connect it to the inlet thread 3 8 inches provide a tight seal Filtration unit must be connected to the water su...

Page 13: ...le copper cable 2 x 2 5 mm2 One end of the cable must be in the technical part near the transformer of spotlight Other end must be near the terminals in the filtering part With the help of terminals m...

Page 14: ...cable is not protected you must install warning tape on top of the cable Under roads cables are laid at a depth of not less than one meter In all other cases the depth of the cable 0 6 m WARNING The t...

Page 15: ...www vsv group com 15 5 ELECTRICAL CONNECTIONS Electrical control panel...

Page 16: ...EL Connection of power supplies is made to the upper terminals of the differential switch observing polarity Power supply cable for pump and transformer of spotlight is connected to terminals accordin...

Page 17: ...or pump and transformer of spotlight in the technical part through O ring Tighten the nut of seal to avoid getting water into the technical part Enter the cable into the connection box and connect the...

Page 18: ...DIAGRAM of HEAT EXCHANGER Connect the filtration unit with electrical control panel according to this scheme electric control panel of filtration unit thermal protection switch switch heat exchanger...

Page 19: ...artment of filtration unit heat exchanger pump electronic thermostat suction pipe discharge pipe expansion tank filtration unit electrical control panel electromagnetic valve non return valve boiler 3...

Page 20: ...phase heater neutral phase ground neutral phase ground Electrical control panel neutral 3 phase ground neutral 3 phase ground main power supply main power supply to electric heater control box cable 2...

Page 21: ...ible hose in the discharge nozzle Enough to keep the hose near the discharge nozzle Stop filling pipelines by water when the air bubbles will stop After filling the pipeline make sure that no leaks in...

Page 22: ...ANING WARNING Replacing contaminated filter membranes can be performed only after turning off the filtration unit Switch off filtration equipment from power supply Remove the pre filter basket and rin...

Page 23: ...r supply clean or replace the filter membrane After cleaning swimming pool again turn off filtration unit remove the cover from the basket replace the dirty membrane on clean Then turn on filtering 9...

Page 24: ...ight and the size of the pool To measure the amount of chlorine you must use the test kits When pH adjusted Water volume Slow chlorination 40 m3 2 tablets 50 m3 2 tablets 60 m3 3 tablets 70 m3 3 table...

Page 25: ...a filtration mode Triggering of safety fuse 6A in the electrical control panel Replace safety fuse 6A 3 Filtration unit spotlight does not shine filtration unit is working Triggering of protection fu...

Page 26: ...during the winter Upon completion of the work do not forget to close the lid of filtration equipment and lock screws 14 Technical Support Center If you have questions or suggestions or need additiona...