26 |
P a g e
DOC-MN-007-03 VCCM600 User Manual
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | www.vox-power.com
Mechanical Dimensions and Mounting
SCREWS
Location
Details
Penetration
Tightening
Baseplate Mount: M1 – M6
Hole diameter = 5.00mm
4mm Baseplate thickness
0.55 NM
Output Module Mount: O1 – O8
M3 CSK
M3 CSK screw, 8mm max length
0.35NM
Input module Mount: F1 – F5
Do not remove or adjust
Do not remove or adjust
Do not remove or adjust
Transformer module Mount: F6 – F7
M3 CSK
M3 CSK screw, 6mm max length
0.35NM
Output Module Terminal
M4 SEM
M4 SEM screw, 8mm max length
0.55NM