EMC Compliance
To support compliance of the final system design with the EMC directive 2014/30/EU, the VCCM600 PSU has been designed and tested to the following
standards.
Typical Conducted emissions
Typical Radiated emissions
For radiated and conducted emissions, compliance of the final system relies on proper installation of the PSU component. The installation guidelines detailed
below should be followed.
ELECTROMAGNETIC COMPLIANCE – EMISSIONS
Phenomenon
Basic EMC Standard
Test Details
Radiated emissions, electric field
EN55011/22
Class B compliant
Radiated emissions, electric field, 30Hz-18GHz.
MIL-STD-461F: RE102 (Ground, Fixed)
Compliant (When mounted in enclosure)
Conducted emissions
EN55011/22, FCC part 15, CISPR 22/11
Class B compliant
Conducted emissions, power leads, 10kHz-10Mhz.
MIL-STD-461F: CE102
Compliant (External filter may be required)
Harmonic Distortion
IEC61000-3-2
Compliant
Flicker & Fluctuation
IEC61000-3-3
Compliant
ELECTROMAGNETIC COMPLIANCE – IMMUNITY
Phenomenon
Basic EMC Standard
Test Details
Electrostatic discharge
IEC61000-4-2
Test level 4: 15kV air, 8kV contact
Radiated RF EM fields
IEC61000-4-3
Test Level 3: (10V/m, 80MHz-2.7GHz) sine wave AM 80% 1kHz
Proximity fields from RF wireless communications
equipment
IEC61000-4-3
Test levels as per IEC60601-1-2:2014 Table 9
Radiated susceptibility, electric field, 2 MHz to 40 GHz.
MIL-STD-461F: RS103
20V
Electrical Fast Transients/bursts
IEC61000-4-4
Test Level 3: (2kV Power, 1kV I/O) 5kHz(ed3) & 100kHz(ed4)
Conducted susceptibility, Bulk cable injection, impulse
excitation
MIL-STD-461F: CS115
Surges
IEC61000-4-5
Test Level 3: 1kV L-N, 2kV L-E
Conducted susceptibility, damped sinusoidal transients,
cables and power leads, 10kHz-100MHz
MIL-STD-461F: CS116
Shipboard Electric Power. Voltage Spike Test
MIL-STD-1399, SECTION 300A
Type 1, 115V 60Hz single phase
Conducted disturbances induced by RF fields
IEC61000-4-6
Test Level 3: 10V, 0.15 to 80Mhz sine wave AM 80% 1kHz
Conducted susceptibility, power leads, 30Hz-150kHz
MIL-STD-461F: CS101
Conducted susceptibility, Bulk cable injection, 10kHz-
200Mhz
MIL-STD-461F: CS114
Power Frequency Magnetic Fields
IEC61000-4-8
Test level 4: 30A/m 50Hz
Radiated susceptibility, Magnetic field, 30Hz-100kHz
MIL-STD-461F: RS101
Voltage Dips
IEC61000-4-11
(2)
0% 10ms, 0% 20ms (Criterion A)
70% 0.5s, 40% 200mS (Criterion A at 240V and Criterion B at 100V)
Voltage Sag Immunity
SEMI-F47-0706
(2)
0% 20mS, 80% 1s,80% 10s,90% continuous (Criterion A)
70% 0.5s, 50% 200mS (Criterion A at 240V and Criterion B at 100V)
Criterion A is achieved for full power when Vin >=160V
Criterion A is achieved at all input voltages when Pout <= 350W
Voltage interruptions
IEC61000-4-11
0% 250/300 cycle as per IEC60601-1-2:2014 (Criterion B)
Aircraft Electric Power Characteristic
MIL-STD-704F
SAC102,104,105,109,110 (MIL-HDBK-704-2) &
SXF102,104,105,109,110 (MIL-HDBK-704-6)
Notes:
1.
Criterion A = No degradation of performance or loss of function.
Criterion B = Temporary degradation of performance or loss of function is allowed, provided the function is self-recoverable.
Criterion C = Temporary loss of function is allowed but requires operator intervention to recover..
2.
Tested at nominal range (100V to 240V). Line deratings applied where appropriate.