23
Electrical schematic (Fig.17)
ENGLISH
17
17
Status
Introductions
Status
Introductions
Solution
Power
indicator
light
Light
Power input normally
Extinguish
Power not supply
Check the external
power source, close
the power switch
Master board fuse blew out
State
indicator
light
Extinguish
Don’t work
Flashing light
Motor falt, it can’t start
normally
Check motor connecting
wires and the rotor
foreign material
Always light
Working
Trick or working time
longer than 25 s
Clear workspace foreign
material, restart to
work
State
indicator
light
Digital
changes
Contdown work
Jump display
Indicate drying time
finished
E1
Motor falut, it can’t
start normally
E2
Trick or working time
longer than 25 seconds
Clear workspaceforeign
material restart to work
E3
The voltage exceeds
15%
E4
The voltage lower than
15%
Check the power supply
circuit
E5
Machine temperatures
higher than 80°C
E6
Master board
temperatures higher
than 80°C
Clear the foreign material
of the air inlet and air
outlet
E8
Fan fault
Check whether the fan
sensor connect is
loosen
Summary of Contents for VORT SUPER DRY
Page 42: ...42 Note ...
Page 43: ...43 Note ...