19
EC / 2
EC / 2
EC / 4
EC / 4
EC / 4
80,7
80,6
79,0
79,1
79,0
8000
10000
12800
16700
21500
3,79
4,73
6,46
8,32
10,59
5,98
7,08
10,37
11,97
23,17
890
911
959
954
949
1031
1028
980
983
980
1,65
1,75
2,16
2,03
2,03
200/250
200/250
200/250
200/250
200/250
253/291
261/301
282/314
278/313
274/305
62,5
62,8
62,0
61,6
61,4
ePM
1
55% (F7) | ePM
10
60% (M5)
67,0
69,0
72,0
70,0
71,0
49,0
50,0
52,0
50,0
50,0
400/3/50
EC / 2
EC / 2
EC / 2
EC / 2
EC / 2
81,1
80,9
80,7
80,7
80,9
1000
2000
3000
4500
6000
0,49
0,91
1,29
2,28
2,82
1,03
1,54
2,50
3,84
5,18
822
802
750
1031
829
1301
1254
1206
1144
1087
1,07
1,24
1,21
1,67
1,67
200/250
200/250
200/250
200/250
200/250
205/226
226/251
216/234
290/319
240/274
52,3
59,8
60,8
60,1
62,5
ePM
1
55% (F7) | ePM
10
60% (M5)
65,0
67,0
63,0
70,0
69,0
49,0
50,0
46,0
52,0
51,0
230/1/50
400/3/50
INSTALLATION OPERATIONS AND MAINTENANCE MANUAL - VORT NRG MEGA-R SERIES
8000
10000
13000
17000
24000
1000
2000
3000
4500
6000
8. TECHNICAL DATA
(1)
ratio between the thermal gain of the inlet air (0 °C) and the thermal loss of the exhaust air (20 °C), both referred to the external temperature, measured under dry
reference conditions, with balanced mass flow and a thermal difference of the internal/external air of 20K, excluding the thermal gain generated by the fan motors and
the internal leakage, in accordance with the provisions of attached V of EU Regulation No 1253/2014
(2)
performance with clean filters
(3)
sound power level calculated in accordance with EN 3744
(4)
sound pressure level measured at 1 m free field distance, in accordance with EN 3744
MODEL
Type of ventilation unit
UVNR-B (Non Residential Ventilation Units - Bidirectional)
Type of drive installed
Analog signal on EC fan (0-10Vdc)
Type of fans
type/nr.
Type of heat recovery system (HRS)
type/nr.
rotary wheel / 1
Winter Thermal Efficiency (ηt_nrvu)
(1)
%
Nominal airflow rate
m
3
/h
Electrical power consumption
kW
Installed electrical power
kW
SFP
int
W/(m3/s)
SFP
lim
2018
W/(m3/s)
Front speed at design range
m/s
External nominal press. Δps, ext
Ret./Supp.
(2)
Pa
Internal pressure drop Δps, int Ret./Supp.
Pa
Fans static efficiency (UE) n.327/2011
%
Max. external
(EN1886)
/ internal leakage percentage
%
L1 | max 5,0 % at +250 Pa
Energy classification filters
Filter pressure switch
present
Sound power level
(3)
dB(A)
Sound pressure level
(4)
dB(A)
Power supply
V/ph/Hz
MODEL
Type of ventilation unit
UVNR-B (Non Residential Ventilation Units - Bidirectional)
Type of drive installed
Analog signal on EC fan (0-10Vdc)
Type of fans
type/nr.
Type of heat recovery system (HRS)
type/nr.
rotary wheel / 1
Winter Thermal Efficiency (ηt_nrvu)
(1)
%
Nominal airflow rate
m
3
/h
Electrical power consumption
kW
Installed electrical power
kW
SFP
int
W/(m3/s)
SFP
lim
2018
W/(m3/s)
Front speed at design range
m/s
External nominal press. Δps, ext
Ret./Supp.
(2)
Pa
Internal pressure drop Δps, int Ret./Supp.
Pa
Fans static efficiency (UE) n.327/2011
%
Max. external
(EN1886)
/ internal leakage percentage
%
L1 | max 5,0 % at +250 Pa
Energy classification filters
Filter pressure switch
present
Sound power level
(3)
dB(A)
Sound pressure level
(4)
dB(A)
Power supply
V/ph/Hz