19
Use
When the appliance is switched on and has been running for 2 minutes, both motors will stop to allow repositioning of the
by-pass valve. The motors will start up again after approximately 1 minutes.
N.B.
: this is a normal system procedure and should not be perceived as a malfunction.
The appliance is rated for continuous duty.
The appliance is wired to a special dedicated control panel, the functions of which are described further on. This model can
be used in combination with a Vortice preheater, which must be fitted and set up by the installer. The minimum distance of
the preheater from the appliance is 500 mm.
User panel Functions
General
(fig.16)
A = “UP” button: list up
B = “DOWN” button: list down
C = SET button: acquire data
D = ESC button: exit
E = display
A panel allows the user to control the operating parameters
of the appliance:
- on/off (NO UK)
- current time/day (NO UK or models with HA)
- operating speed
- required room temperature
- selection of bypass function
- “HA” operation mode (for models provided with HA module)
The function of the ESC button, unless otherwise stated, is always that of quitting without saving data.
Summary of icons displayed on the panel (Fig.17)
11. P2 time profile: see “User Menu” section (NO UK or models with HA)
12. HA: (only models with HA)
14. actual operating speed: the icons light up permanently to indicate which of the 3 speeds is currently selected.
15. system stand-by status: the icon lights up permanently to indicate that the appliance is in stand-by (powered up but with
the motors off), due to the activation of an alarm (UK), or because the system is shut down (NO UK); the icon blinks
(NO UK) to indicate that the appliance is in stand-by after programming time bands (see section on “Programming of
time profiles”);
16. the icon lights up to indicate that an alarm has been tripped; when the icon blinks, this indicates that an alarm with
manual reset has been tripped (see “View alarms menu”)
17. bypass function: the icon indicates: (see also "Activation of bypass function" paragraph)
ENGLISH
esc
set
16
16
By-Pass
/ °C
1
2
3
4
5
6
7
P1
P2
Prg
A
B
C
D
E
FILT
HA
17
17
8 9 10 11 12
14
15
16 17 19
1 2 3 4 5 6 7
20
21
1÷7day of the week (NO UK or models with HA): 1=Monday,
2=Tuesday, etc.
8. filter alarm: this icon lights up to warn that the filters
should be replaced within three months; if the filters are
not renewed by the end of this period, the system will
lock up (only UK models) and the filter error message
FILT appears (see "View alarm menu")
9. no-frost function: the icon lights up permanently when the
no-frost procedure is active; the icon will flash to indicate
a “no-frost timeout”: in this instance the no-frost
procedure has proved insufficient and the appliance goes
into protected mode for one hour, with the motors off,
following which it will restart automatically.
10. P1 time profile: see “User Menu” section ( NO UK or
models with HA)