Installation drawing
Selection of location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please
consult the local dealer:
spread in the air.
2.The place with high-frequency devices (such as welding machine,medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
1.There should be noobstruction near air inlet and air outlet.
2.Choose a place where the condensation water can be dispersed easily and won't affect
other people.
3.Choose a place which is convenient to connect the outdoor unit and near the power
socket.
4.Choose a place which is out of the reach of children.
5.The place should be able to withstand the weight of indoor unit and won't increase noise
and vibration.
7.Don't install the indoor unit right above an electric appliance.
Indoor unit
Drainage pipe
At least 250cm
At least 15cm
At least 50cm
Space to the
obstruction
Spa
ce
to
the
c
eili
ng
Space to the obstruction
At least 30cm
At least 15cm
At least 15cm
Space to the wall
Space to the wall
Space to the wall
At least 30cm
Space to the obstruction
At least 15cm
At least 200cm
Space to
the obstruction
At least 300cm
Space to the obstruction
Space to the floor
47