11
• Do not use th
i
s appl
i
ance for funct
i
ons other than
those descr
i
bed
i
n th
i
s booklet
.
• After remov
i
ng the appl
i
ance from
i
ts packag
i
ng,
ensure that
i
t
i
s complete and undamaged
.
If
i
n
doubt contact a profess
i
onally qual
i
f
i
ed electr
i
c
i
an or
Vort
i
ce*
.
Do not leave packag
i
ng w
i
th
i
n the reach of
ch
i
ldren or
i
nf
i
rm persons
.
• If you dec
i
de to stop us
i
ng the appl
i
ance, sw
i
tch
i
t
off and d
i
sconnect
i
t from the power supply
.
• Store the appl
i
ance out of the reach of ch
i
ldren and
i
nf
i
rm persons
i
f you dec
i
de to d
i
sconnect
i
t from the
power supply and no longer use
i
t
.
• Do not use th
i
s appl
i
ance
i
n potent
i
ally explos
i
ve or
flammable atmospheres or to extract ac
i
d or
corros
i
ve fumes (f
i
g
.
1)
.
• The
i
nter
i
or of the appl
i
ance must only be cleaned
by profess
i
onally qual
i
f
i
ed personnel
.
• If the appl
i
ance
i
s
i
nstalled at a he
i
ght of less than
2
.
5 metres from the floor,
i
t
i
s obl
i
gatory to
i
nstall
protect
i
ons for mov
i
ng parts,
i
n the form of the
safety mesh frame and grav
i
ty shutter (f
i
g
.
4-5)
.
• If the selected product exceeds 70 dB(A), adequate
no
i
se damp
i
ng must be f
i
tted when
i
t
i
s
i
nstalled, or
su
i
table personal protect
i
ve equ
i
pment used
.
Model
Lp dB(A) (3m)
E 252 M
71
• Do not make mod
i
f
i
cat
i
ons of any k
i
nd to th
i
s
appl
i
ance
.
• Regularly
i
nspect the appl
i
ance for v
i
s
i
ble defects
.
If any faults are found, do not operate the appl
i
ance;
contact Vort
i
ce*
i
mmed
i
ately
.
• If the appl
i
ance does not funct
i
on correctly or
develops a fault, contact Vort
i
ce*
i
mmed
i
ately
.
Ensure that only genu
i
ne or
i
g
i
nal Vort
i
ce spares are
used for any repa
i
rs
.
• Should the appl
i
ance be dropped or suffer a heavy
blow, have
i
t checked
i
mmed
i
ately by Vort
i
ce*
.
• Th
i
s appl
i
ance must only be
i
nstalled
and serv
i
ced, externally or
i
nternally,
by profess
i
onally qual
i
f
i
ed personnel
.
• Sw
i
tch off the appl
i
ance at the
i
nstallat
i
on
'
s ma
i
n
sw
i
tch: a)
i
f the appl
i
ance does not funct
i
on
correctly; b) before clean
i
ng the
i
ns
i
de or outs
i
de of
the appl
i
ance, c)
i
f the appl
i
ance
i
s not to be used
for any length of t
i
me
.
• Ensure that the electr
i
cal system to wh
i
ch the
appl
i
ance
i
s connected compl
i
es w
i
th appl
i
cable
standards
.
• Spec
i
f
i
cat
i
ons for the power supply must correspond
to those on the appl
i
ance
'
s data plate
.
•
The c
i
rcu
i
t
i
n wh
i
ch the appl
i
ance
i
s
i
nstalled
must have an overload protect
i
on dev
i
ce
cal
i
brated to su
i
t the nom
i
nal current shown on
the appl
i
ance's data plate.
• Th
i
s appl
i
ance must be connected to an eff
i
c
i
ent
earth
i
ng system
i
n compl
i
ance w
i
th appl
i
cable safety
standards
.
If
i
n doubt, ask a qual
i
f
i
ed electr
i
c
i
an to
check your system
.
• The electr
i
cal power supply/socket to wh
i
ch the
appl
i
ance
i
s to be connected must be able to
prov
i
de the max
i
mum electr
i
cal power requ
i
red by
the appl
i
ance
.
If
i
t cannot do so, arrange for a
qual
i
f
i
ed electr
i
c
i
an to make the necessary
mod
i
f
i
cat
i
ons
.
• When
i
nstall
i
ng the appl
i
ance, f
i
t a mult
i
-pole
thermomagnet
i
c cutout, w
i
th a contact gap of at
least 3 mm
.
• If the appl
i
ance
i
s
i
nstalled outdoors, ensure that
adequate weather protect
i
on
i
s prov
i
ded
.
• Operat
i
ng temperature from -25°C to +40÷70°C
.
• Do not cover the appl
i
ance
'
s
i
ntake and outlet
.
• Only f
i
t the spec
i
f
i
ed accessor
i
es over the
i
ntake
and outlet
.
• Make sure that the room
i
s adequately vent
i
lated to
ensure proper a
i
r c
i
rculat
i
on
.
• Do not allow dust to bu
i
ld up on the motor
.
Th
i
s can
prevent correct cool
i
ng
.
Regular ma
i
ntenance
i
s
essent
i
al for correct funct
i
on
i
ng and to ach
i
eve the
declared levels of performance
.
Follow the
i
nstruct
i
ons
i
n the f
i
gures on page 44 to perform the
necessary mechan
i
cal ma
i
ntenance
.
N.B.
Do not submerge the electr
i
c motor
i
n water or
any other l
i
qu
i
d.
Warn
i
ng:
th
i
s symbol
i
nd
i
cates precaut
i
ons that must be taken to avo
i
d
i
n
j
ury
!
WARNING - CAUTION
Caut
i
on:
th
i
s symbol
i
nd
i
cates precaut
i
ons that must be taken to avo
i
d damag
i
ng the appl
i
ance.
!
*or an author
i
zed Vort
i
ce dealer
i
f you are outs
i
de the UK-Ireland terr
i
tory
DESCRIPTION AND OPERATION
ENGLISH
The product you have purchased
i
s a low pressure,
i
ndustr
i
al ax
i
al fan for extract
i
on d
i
rectly to the outs
i
-
de
.
It
i
s des
i
gned for use
i
n appl
i
cat
i
ons where no
load loss
i
s to be be overcome
.
It must not be used to
extract dusty a
i
r or ac
i
d or corros
i
ve fumes (f
i
g
.
1)
.
• The thermal protection system on three-phase
motors should be connected to a device that cuts
off the power supply if the coil temperature
exceeds its safety limit.
773 - Vorticel:Layout 1 14/07/2010 17.25 Pagina 3
Summary of Contents for E 254T ATEX
Page 8: ...8 9 5 6 ...
Page 35: ...3 35 773 Vorticel Layout 1 14 07 2010 17 25 Pagina 18 ...
Page 40: ...43 13 15 14 40 402 pag mod di 148 qxp 12 06 2007 16 46 Pagina 26 ...
Page 42: ...45 19 18 21 20 42 402 pag mod di 148 qxp 12 06 2007 16 46 Pagina 28 ...
Page 50: ...Note 50 402 pag mod di 148 qxp 12 06 2007 16 46 Pagina 36 ...
Page 51: ...51 Note 402 pag mod di 148 qxp 12 06 2007 16 46 Pagina 37 ...