3.8
Keypad
General
So that the V910 Uk0 gateway can use the keypad of the end device, the keypad must be activated in
the end device during the initialization of the gateway.
If you have purchased a V615 industrial call station with keypad from Vonamic GmbH, the hardware
and software modification has already been done by the manufacturer. If you have carried out the
conversion yourself, make sure that the connector to the keypad is correctly inserted and that the
keypad is screwed in securely. Furthermore, it is necessary to update the V615 website to the version
"
V615
Keypad (http.tsk)" and the keypad is activated on the website.
The keypad is exchanged for the lower double toggle of the device. This will replace the direct selection
buttons 5 + 6 with the keypad. By activating the keypad, the keys 3 + 4 are assigned fixed functions
which are required for using the kepad:
Example image
Dial:
Press and hold Establishes a connection to the previously dialed number. The
connection type can be selected by entering a prefix.
Cancel:
This key clears the input memory so that all selected digits are deleted. With an existing
SIP connection, this key is used to end the call.
Dial
cancel