9
TOP STRIKE AND COVERS
9a
Adjust top strike as necessary, then install the third
strike screw to fi x the strike position.
Metal
Wood
#25 x
³⁄₄
" Deep
#10-24
¹⁄₈
" Drill
Pilot 1" Deep
OR
(metal)
(wood)
9b
For fi re devices, prepare door edge and cover plate.
I
Fire application only
I
Intumescent must be properly aligned before exposed
adhesive contacts cover plate. Adhesive is permanent and
not repositionable.
³⁄₁₆
" Drill, Pilot 1" Deep x2
Insert plastic
anchors
Peel adhesive backing from
intumescent and apply to
back side of cover plate
b-1
b-1
b-2
9c
Install cover plate to door edge, then completely
tighten down center case screws.
For non-fire devices, first
prepare door edge
¹⁄₈
" Drill, Pilot 1" Deep x2
c-2
c-1
9d
Install center case cover.
Remove protective
film from pushbar