Stopping
Allow the engine to idle (in neutral) for a couple of minutes before turning it off. This evens out the temperatures
inside the engine, and stops after-boiling.
I
mportant!
The procedure described above is especially important if the engine has been run at heavy
loads.
I
mportant!
If the engine stops abnormally, try to locate the problem and make the repairs needed before
starting again. After starting the engine, make sure it runs properly.
Stop
1. Disengage the reversing gear by putting the con-
trol lever in neutral.
2. Turn the key to stop position “
S
”. Keep the key
turned until the engine stops. The key will auto-
matically return to the “
0
” position when it is re-
leased and can then be removed.
important!
Never switch off the main swit-
ches while the engine is running. This could da-
mage the alternator.
important!
Never switch off the main swit-
ches before the starter key is turned off (is in
“
0
” position or removed). This could damage the
electrical system.
auxiliary stop
If a fault occurs that prevents you stopping the engine in
the normal way, you can stop it by pressing the emer-
gency button.
If the engine has been stopped using the emergency
stop button, the button locks in the down position. In
order to be able to restart the engine, the button must
be reset to its original position. To do this, pull the
button upwards until you hear a click.
Warning!
Working with, or going close to a
running engine is a safety risk. Watch out for ro-
tating components and hot surfaces.
54