Fuel System
Group 23: Fuel System
Feed pump maximum suction height
0.8 m (2.62 ft)
Feed pressure
15–25 kPa (2.2–3.6 PSI)
Fuel injection pump
Type
Inline horizontal pump
D1-13-A/B/F
D1-20-A/B/F
D1-30-A/B/F
D2-40-A/B/F
Injection start, before TDC
20° ±1°
20° ±1°
20° ±1°
22° ±1°
Pump element diameter
5 mm (0.1968")
5 mm (0.1968")
6 mm (0.2362")
5.5 mm (0.2165")
Stroke
6.5 mm (0.2559")
6.5 mm (0.2559")
6 mm (0.2362")
6 mm (0.2362")
Injectors
Opening pressure (at checks)
D1-13-A/B/F, D1-20-A/B/F
11.96 MPa (1735 PSI)
D1-30-A/B/F
13.9 MPa (2016 PSI)
D2-40-A/B/F
14.7 MPa (2132 PSI)
Jet angle
4°
Exhaust System
Max. permissible exhaust back pressure in exhaust line at max. rpm, all engines
20 kPa (2.9 PSI)