Installation and Operation Manual | VOLTI Home Charging Device
11
4. Open the installation cover of the wire connection and adjustment compartment. Adjust the
charging station output current and power via the current switch according to the installed power
capacity of the installation location.
Switch
Position
Allowed
Current
Value
(Amperes)
1 Phase
Output
Power
(kW)
3 Phase
Output
Power
(kW)
0
32
7.4
22
1
16
3.4
11
2
13
3
8.9
3
10
2.3
6.9
4
8
1.8
5.5
5
6
1.4
4.1
6
Reserved
0
0
7
Reserved
0
0
8
Reserved
0
0
9
Reserved
0
0
5. Attach the ring terminals to the end of the wires that will be used to supply energy to the charging
station.
Ayarlanan
Akım
Değeri (Amper)
Minimum
Kablo kesiti mm2
32
6 mm
2
16
2,5 mm
2
13
1,5 mm
2
10
1,5 mm
2
8
1,5 mm
2
6
1,5 mm
2