Exhaust  fan,  centre  lamp  and  heat  lamps  may be operated individually or  

   

 

all together.
CAUTION: If the lamps are left on for extended periods without the exhaust fan, the 
internal over temperature switch (OTS) may close causing the fan to operate
automatically to keep the unit operating at a safe temperature. When the appliance
has cooled sufficiently the fan will be automatically switched off.

 

WARNING: Ensure the appliance is switched off from the mains power supply first 
using the all-pole switch installed in the fixed wiring. Lamps must be allowed to 
cool sufficiently before cleaning or replacement.
It is recommended the appliance be checked and cleaned every 2 years. Wipe facia 
with care using a damp cloth. The lamps may be cleaned with liquid glass cleaner. 
The inner housing and fan blade may be cleaned with a dry cloth or with a vacuum 
cleaner with suitable brush attachment.
Clean  the  exhaust  ducting  kit  (where  fitted),  ensuring  there  are  no 
obstructions along the way or at the exit.

CAUTION: To prevent damage to the appliance do not use alkaline cleaning agents 
or solvents when cleaning, use a soft cloth and a mild detergent.

Ensure lamps are screwed well in after replacement to give good electrical contact.
Clean all heat lamps ensuring no finger prints or oil residues are left on them 
after insertion to prolong the lamp life.

Figure 1. Wiring Diagram 
VBHE-2L 

VBHE-4L 

CAUTION: Replacement with any other lamps other than those listed below may 
cause damage to the appliance and void the warranty