© Voltex Electrical 2015. All Rights Reserved.
®
Exhaust fan, centre lamp and heat lamps may be operated individually or
all together.
CAUTION: If the lamps are left on for extended periods without the exhaust fan, the
internal over temperature switch (OTS) may close causing the fan to operate
automatically to keep the unit operating at a safe temperature. When the appliance
has cooled sufficiently the fan will be automatically switched off.
WARNING: Ensure the appliance is switched off from the mains power supply first
using the all-pole switch installed in the fixed wiring. Lamps must be allowed to
cool sufficiently before cleaning or replacement.
It is recommended the appliance be checked and cleaned every 2 years. Wipe facia
with care using a damp cloth. The lamps may be cleaned with liquid glass cleaner.
The inner housing and fan blade may be cleaned with a dry cloth or with a vacuum
cleaner with suitable brush attachment.
Clean the exhaust ducting kit (where fitted), ensuring there are no
obstructions along the way or at the exit.
CAUTION: To prevent damage to the appliance do not use alkaline cleaning agents
or solvents when cleaning, use a soft cloth and a mild detergent.
Ensure lamps are screwed well in after replacement to give good electrical contact.
Clean all heat lamps ensuring no finger prints or oil residues are left on them
after insertion to prolong the lamp life.
Figure 1. Wiring Diagram
VBHE-2L
VBHE-4L
CAUTION: Replacement with any other lamps other than those listed below may
cause damage to the appliance and void the warranty
OPERATION
CARE INSTRUCTIONS
REPLACEMENT LAMPS