background image

 

 

 

2.2 Technical specifications 

 

Ripple and noise : 

5% 

Voltage regulation : 

0.5% 

Current regulation :

 

1%  

Load regulation : 

0.5% 

Display accuracy: ±1%±1 digit 
Control accuracy: 

1%  

Protection: Over-current, Over-voltage, Over-temperature 
Input voltage: AC220V±10% 50/60Hz 

Working conditions: -100C -400C, relative humidity<90%, no condensation 
Storage conditions: -200C-800C, relative humidity<80% 
Ventilation: minimum of 50cm of open space around the rectifier is required for good ventilation 
Elevation: 

1500 Meters 

 

 

 
III. The operation procedures   
 

1. Check to ensure the AC plug is secure and wired correctly for the polarity. Check to ensure the output 

is connected correctly and securely. 

2. Check to ensure power switch and output switch are in "OFF" state, and the output adjustment knob 

Summary of Contents for HY10500EX

Page 1: ...HIGH POWER PLATING RECTIFIER USER MANUAL VOLTEQ ...

Page 2: ... you are running inductive load like magnetic coils DC motors stepper motors etc make sure to change the voltage current slowly and NEVER turn the rectifier on or off with a inductive load connected Warning Do not attempt to inspect or repair the rectifier unless it has been powered off for at least one minute Warning The copper wires terminals maybe be hot after the rectifier has been turned on W...

Page 3: ... voltage as well as constant current DC rectifier These rectifiers are great choice for anodizing plating electrolysis hydrogen generation and other applications that require high output power The table below list the current models available from Volteq Model Output Voltage Output Current AC Voltage Maximum AC Current HY10500EX 0 10V 0 500A AC220V 10 50 60Hz 30A HY15200EX 0 15V 0 200A AC220V 10 5...

Page 4: ... 1 Power ON OFF switch 2 Output adjustment knob 3 Output ON OFF switch 4 Selection switch for CV constant voltage and CC operation 5 Amp meter 6 Volt meter ...

Page 5: ...C relative humidity 90 no condensation Storage conditions 200C 800C relative humidity 80 Ventilation minimum of 50cm of open space around the rectifier is required for good ventilation Elevation 1500 Meters III The operation procedures 1 Check to ensure the AC plug is secure and wired correctly for the polarity Check to ensure the output is connected correctly and securely 2 Check to ensure power ...

Page 6: ...to the desired level IV Maintenance Routine inspection and maintenance is required for prolonged working life of the rectifiers 1 Clean dust off the inside of the rectifier and cooling fan 2 Clean off the oxide layer that may occur on the output copper wires and connectors 3 Check to ensure that cooling fan is in good working condition all the time replace the fan if it fails 4 Regularly check and...

Page 7: ...sitive and negative terminals maybe loose Circuit breaker jumps during operation some components may have failed internally Output voltage or current is not stable voltage or current meter may have gone bad Case is not grounded and is electrically hot the environment maybe too humid some internal components may have failed All products from Volteq come with 1 year full manufacturer s warranty For ...

Reviews: