at the minimum position. 

3. Plug into AC outlet, and then turn on the power switch (1). Check to make sure the fan is working. 

4. Turn on the output (3). Select switch (4) to either "CV" or "CC" as your operating mode. If "CV" is 

selected, the output voltage will be stable while the output current will change with the load; likewise, if 

"CC" is selected, the output current will be stable while the voltage will change with the load. 

5. Adjust knob (2) to set the output to the desired level.

 

 

IV. Maintenance   

 
Routine inspection and maintenance is required for prolonged working life of the rectifiers: 
 

1. Clean dust off the inside of the rectifier and cooling fan. 

2. Clean off the oxide layer that may occur on the output copper wires and connectors. 

3. Check to ensure that cooling fan is in good working condition all the time, replace the fan if it fails. 

4.  Regularly  check  and  ensure  that  switch  and  circuit  breaker  are  in  good  working  condition  and  all 

connectors are secure and firm. 

5. The rectifier should not sit idle for more than a year, as the capacitor may change its characteristics if 

not charged for a long time. 

 

 

 

Summary of Contents for HY10500EX

Page 1: ...HIGH POWER PLATING RECTIFIER USER MANUAL VOLTEQ ...

Page 2: ... you are running inductive load like magnetic coils DC motors stepper motors etc make sure to change the voltage current slowly and NEVER turn the rectifier on or off with a inductive load connected Warning Do not attempt to inspect or repair the rectifier unless it has been powered off for at least one minute Warning The copper wires terminals maybe be hot after the rectifier has been turned on W...

Page 3: ... voltage as well as constant current DC rectifier These rectifiers are great choice for anodizing plating electrolysis hydrogen generation and other applications that require high output power The table below list the current models available from Volteq Model Output Voltage Output Current AC Voltage Maximum AC Current HY10500EX 0 10V 0 500A AC220V 10 50 60Hz 30A HY15200EX 0 15V 0 200A AC220V 10 5...

Page 4: ... 1 Power ON OFF switch 2 Output adjustment knob 3 Output ON OFF switch 4 Selection switch for CV constant voltage and CC operation 5 Amp meter 6 Volt meter ...

Page 5: ...C relative humidity 90 no condensation Storage conditions 200C 800C relative humidity 80 Ventilation minimum of 50cm of open space around the rectifier is required for good ventilation Elevation 1500 Meters III The operation procedures 1 Check to ensure the AC plug is secure and wired correctly for the polarity Check to ensure the output is connected correctly and securely 2 Check to ensure power ...

Page 6: ...to the desired level IV Maintenance Routine inspection and maintenance is required for prolonged working life of the rectifiers 1 Clean dust off the inside of the rectifier and cooling fan 2 Clean off the oxide layer that may occur on the output copper wires and connectors 3 Check to ensure that cooling fan is in good working condition all the time replace the fan if it fails 4 Regularly check and...

Page 7: ...sitive and negative terminals maybe loose Circuit breaker jumps during operation some components may have failed internally Output voltage or current is not stable voltage or current meter may have gone bad Case is not grounded and is electrically hot the environment maybe too humid some internal components may have failed All products from Volteq come with 1 year full manufacturer s warranty For ...

Reviews: