background image

O.  Specifications 

 

Model 

BC-1230P 

BC-1240P 

BC-1260P 

Output 

Charge Voltage Selections (all models) 

Absorption V 

Float V 

Standby V 

WET 

14.5V 

13.5V 

Float Voltage less 4% 

LiFePO4   

14.6V 

13.6V 

N/a 

LiFePO4 #2 

14.4V 

13.6V 

N/a 

AGM    (Default setting) 

14.4V 

13.2V 

Float Voltage less 4% 

AGM #2 

14.3V 

13.4V 

Float Voltage less 4% 

GEL #2 

14.2V 

13.7V 

Float Voltage less 4% 

CALCIUM 

15.1V 

13.8V 

Float Voltage less 4% 

User Define 1 

12V - 16V Adj 

User Define 2 

12V - 16V Adj 

Lead Crystal 

14.7V 

13.6V 

N/a 

Equalization 

  15.5V 

Maximum Output Charging Current (Continuous) 

30A 

40A 

60A 

Recommended Battery Capacity Range 

(for all battery type) 

12 – 300AH 

15 – 400AH 

20 - 600AH 

Soft Start Bulk Charge 
Battery Voltage to Trigger (cut-in) Soft Start 

Bulk Charge Mode 

<10.5V 

Soft Start Bulk Charge Current (Current Limit) 

1/2 of the charging current  1/2 of the charging 

current 

1/2 of the charging 

current 

 
Ripple and Noise (Peak to Peak) 

<200mV 

<200mV 

<200mV 

Efficiency at Maximum Power (230V) 

>83% 

>83% 

>83% 

 
Dual Bank Charging (Battery must be of same type) 

Yes 

Yes 

Yes 

Input 

AC Voltage Range 

200 – 240V 50Hz~ 

AC Current at Full Load (230V) 

2.5A 

3.5A 

5.0A 

Protection 

Overload 

90-110% Rated Output Current or 50% Rated Output Current (Soft Charge) 

Protection Type : Constant Current Limiting, recovers Automatically after 

Fault Condition is Removed. 

Short Circuit 

Recovers Automatically if Fault Condition is Removed within 20 seconds 

Otherwise the charger will shut down until re-start the charger again 

Reverse Polarity 

Automotive type Blade Fuse 

Over Temperature 

Protection Type: Shut Down 

OVP Output Over Voltage 

Yes 

Cooling 

Cooling Method 

Thermostatic, Variable Speed Fan 

Indicators 

4-Stage Battery Charger   

Yes 

Charge Phase Bulk / Absorption / Float 

Yes 

Fault Mode 

Yes 

Over Temp   

Yes 

Charger ON 

Yes 

Fuses 

AC Fuses at IEC AC Power Socket 

T3.15A 

T4A slow blow 

F8A 

DC Car Blade Fuse 

25Ax2 

30Ax2 

30Ax3 

Accessories 

Supplied Accessories 

Remote Temperature sensor, ac cable, spare ac fuse at socket, spare dc 

fuses, CD Software, USB Cable 

Optional Accessory 

Remote Control Panel (Model:HBR-3100) 

Approvals 

Safety :   

CE: EN 60335 

SAA: AS/NZS 60335.1, AS/NZS 60335.2.29 

  (Include clause 21.102: Vibration Test) 

Yes 

EMC: EN 55014; EMF: EN50366 

Yes 

Others 

Dimensions and Weight 

200x80x260mm ; 3.2kg 

200x80x260mm ; 

3.2kg 

200x80x320mm ; 4.2kg 

Remarks 

All values are based on the standard ambient temperature 25°C and pressure 0.1Mpa. 

Summary of Contents for BC- 1260P

Page 1: ...ause risk of fire electric shock or equipment damage Disconnect the mains supply before connecting or disconnecting the links to the battery If the charger does not work properly or if it has been dam...

Page 2: ...l AGM LiFePO4 Calcium Calcium and now also Lead Crystal batteries There are also two User programmable charging profiles for the professional users via the USB port by personal computer In addition th...

Page 3: ...l s 10 Automatic Cooling Fan 11 Inlet AC socket with Mains fuse holder 12 Temperature Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at l...

Page 4: ...he operation of connected powered appliance or connections E Battery Charger Installation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check...

Page 5: ...sorption stage Charging current will now decrease gradually until a pre set value at which the charger then automatically switches to Float Stage The max Absorption time is also controlled by the time...

Page 6: ...zation by charger itself Once Auto is selected the charger will start Equalization automatically if charger stays in Float mode for over 21 days After entering into this mode the Absorption indicator...

Page 7: ...te temp sensor at 60 C Flashing Solid ON OFF Manual power on off reset after fault cleared Alarm flash Buzzer on Bat Over Temp Fan not working or stuck Flashing Flashing OFF Manual power on off reset...

Page 8: ...ad and charger not balanced Battery does not get full charge All indicator LED work normally and sequentially OTP LED flashing Bad battery connection Battery type select switch in wrong setting Batter...

Page 9: ...ad 230V 2 5A 3 5A 5 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is...

Page 10: ...e set max power level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mou...

Page 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Page 12: ...Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Equalization mode Equalization selection slide swi...

Reviews: