background image

IV.  Programming using the optional remote 

 

A.  Pressing Func. Button to display “Scrolling” or until any setting you want to display 

B.  Pressing Set button to confirm 

 

 

Remote Panel “Scrolling” Menu Options 

 

1. Charger Name 

Display charger model 

2. Charger Status 

Display Bulk / Absorption / Float 

3. Battery Type 

Display the battery type selected 

4. Fault 

Display the “No Fault Found” or Type of fault   

5. Bat. Bank 1 

Display the charging voltage and current of Bank 1 

6. Bat. Bank 2 

Display the charging voltage and current of Bank 2 for other models in this series 

7. Bat. Bank 3 

Display N.A as no Bank 3 for this series of charger   

8. Total Run Time 

Display units total run time 

9. Output Power Level  Display current output level 
10. Software Version 

Displays the current control software version 

 

Remote Short cut 

 

1.  Press and hold the SET button for 5 seconds and release the button to enter Equalization mode. 

 

(Equalization selection slide switch on main unit should be selected at manual position) 

 

2.  Press and hold the Func. button for 5 seconds and release the button to force the charger to Float mode. 

 

V.  Fault Indication 

 

1. Charger High Temp  :  Charger over temperature 

2. Bat Over Temp 

:  Battery temperature over 60°C as detected by remote sensor 

3. Output V High 

:  Output over voltage 

4. Overload 

:  Overload (OCP) 

5. Output Shorted 

:  Output short circuit 

6. Wrong Polarity 

:  Output reverse polarity 

7. Fan Fault 

:  Fan stuck or not working 

8. DC Voltage Low 

:  Bulk 4 hour soft start timer charging reaches 4 hours (Battery is less than 24V) 

 

 

Q. 

HBC SOFTWARE INSTALLATION 

 

PLEASE REFER TO THE USER MANUAL IN THE CD FOR INSTALLATION AND APPLICATION PROCEDURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV.7  12/2018 

7673-3130-3527 

 

Summary of Contents for BC- 1260P

Page 1: ...ause risk of fire electric shock or equipment damage Disconnect the mains supply before connecting or disconnecting the links to the battery If the charger does not work properly or if it has been dam...

Page 2: ...l AGM LiFePO4 Calcium Calcium and now also Lead Crystal batteries There are also two User programmable charging profiles for the professional users via the USB port by personal computer In addition th...

Page 3: ...l s 10 Automatic Cooling Fan 11 Inlet AC socket with Mains fuse holder 12 Temperature Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at l...

Page 4: ...he operation of connected powered appliance or connections E Battery Charger Installation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check...

Page 5: ...sorption stage Charging current will now decrease gradually until a pre set value at which the charger then automatically switches to Float Stage The max Absorption time is also controlled by the time...

Page 6: ...zation by charger itself Once Auto is selected the charger will start Equalization automatically if charger stays in Float mode for over 21 days After entering into this mode the Absorption indicator...

Page 7: ...te temp sensor at 60 C Flashing Solid ON OFF Manual power on off reset after fault cleared Alarm flash Buzzer on Bat Over Temp Fan not working or stuck Flashing Flashing OFF Manual power on off reset...

Page 8: ...ad and charger not balanced Battery does not get full charge All indicator LED work normally and sequentially OTP LED flashing Bad battery connection Battery type select switch in wrong setting Batter...

Page 9: ...ad 230V 2 5A 3 5A 5 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is...

Page 10: ...e set max power level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mou...

Page 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Page 12: ...Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Equalization mode Equalization selection slide swi...

Reviews: