IV. Programming using the optional remote
A. Pressing Func. Button to display “Scrolling” or until any setting you want to display
B. Pressing Set button to confirm
Remote Panel “Scrolling” Menu Options
1. Charger Name
Display charger model
2. Charger Status
Display Bulk / Absorption / Float
3. Battery Type
Display the battery type selected
4. Fault
Display the “No Fault Found” or Type of fault
5. Bat. Bank 1
Display the charging voltage and current of Bank 1
6. Bat. Bank 2
Display the charging voltage and current of Bank 2 for other models in this series
7. Bat. Bank 3
Display N.A as no Bank 3 for this series of charger
8. Total Run Time
Display units total run time
9. Output Power Level Display current output level
10. Software Version
Displays the current control software version
Remote Short cut
1. Press and hold the SET button for 5 seconds and release the button to enter Equalization mode.
(Equalization selection slide switch on main unit should be selected at manual position)
2. Press and hold the Func. button for 5 seconds and release the button to force the charger to Float mode.
V. Fault Indication
1. Charger High Temp : Charger over temperature
2. Bat Over Temp
: Battery temperature over 60°C as detected by remote sensor
3. Output V High
: Output over voltage
4. Overload
: Overload (OCP)
5. Output Shorted
: Output short circuit
6. Wrong Polarity
: Output reverse polarity
7. Fan Fault
: Fan stuck or not working
8. DC Voltage Low
: Bulk 4 hour soft start timer charging reaches 4 hours (Battery is less than 24V)
Q.
HBC SOFTWARE INSTALLATION
PLEASE REFER TO THE USER MANUAL IN THE CD FOR INSTALLATION AND APPLICATION PROCEDURE
REV.7 12/2018
7673-3130-3527