background image

F.  Normal 4-Stage (IUoU) Charging Operation   

 

 

The 4-stage IUOU charge algorithm ensures fast, complete and at the same time gentle charging of the lead acid battery. 

 

 

Charging Profile 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stage 1.

 THE I-PHASE. [BULK mode] Constant current charging, Bulk LED is ON. 

 

 

Normally the battery is charged at constant maximum current until it rises to the selected Absorption voltage level. 

 

The charging voltage changes with the battery voltage. 

 

 

Soft-Start Bulk Charging: 

Bulk LED flashes slow

 

 

If at the start of charging, the battery voltage is less than 10.5V, the bulk charge current is reduced to half of what the charging 

 

current selector is set at, until the battery voltage rises to 12.0V. This soft start charging mode will repeatedly check the voltage 

 

every 10 minutes until the battery voltage rises to 12.0V. If the battery voltage cannot reach 12.0V after 4 hours, unit will go into 

 

fault mode and output is shut off. If this happens it is advisable to disconnect any active heavy load on the battery and check the 

 

  chargers output current setting. To reset the charger; switch it off for longer than 30seconds, then back on. 

       

      Remark:   

      If the battery keeps the charger at Bulk mode for 12 hours, the charger will automatically switch to Float mode

 

 

Stage 2.

 THE UO-PHASE. [ABSORPTION mode] Constant voltage charging, Absorption LED is ON. 

 

When the battery voltage reaches the selected Absorption voltage level.(Battery select Switch 4).     

The  charging  mode  switches to Constant voltage charging  (Absorption stage). Charging current will now decrease gradually 

until a pre-set value at which the charger then automatically switches to Float Stage. The max. Absorption time is also controlled 

by the time in Bulk charge, and battery type selected. 

      

 

Stage 3. 

THE UO-PHASE. [FLOAT mode] Constant voltage charging, Float LED is ON. 

 

 

In Float stage, the battery is full and only takes in the amount of current necessary for maintaining the capacity.   

 

The float voltage is preset according to the type of battery selected by the user.(Battery select Switch 4).   

 

If the charger stays in this mode with charging current less than 5A for over 72 hours. Then the charger will automatically 

 

Switch into the Standby mode. 

 

 

Stage 4. 

THE UO-PHASE. [STANDBY mode] Constant voltage charging, Float LED is ON. 

 

 

Note; Only applies to certain Battery types [See Specs section. O]. 

 

In Standby stage, The charging voltage at this mode will be 4% less than the standard Float voltage. 

 

This lower charging voltage level reduces drying out of electrolyte liquid & helps to prolong the life of an inactive battery. 

     

    

New Cycle Charge every 21 days 

 The Charger will automatically start a new charging cycle of Bulk to Absorption to Float every 21 days in either standby or float 

mode. This   new cycle of charging will refresh the battery to prevent separation of the electrolyte & keep the electrode plates in 

good working condition during long periods of storage of the Caravan/RV or back up battery applications. 

 

Remark: 

 

Charger can provide the full selected max current in Float or Standby mode. If battery voltage drops to 12.5V for approx. 10 

 

minutes in Float or Standby mode: The charger will start a new cycle of charging. 

 

 

Summary of Contents for BC- 1260P

Page 1: ...ause risk of fire electric shock or equipment damage Disconnect the mains supply before connecting or disconnecting the links to the battery If the charger does not work properly or if it has been dam...

Page 2: ...l AGM LiFePO4 Calcium Calcium and now also Lead Crystal batteries There are also two User programmable charging profiles for the professional users via the USB port by personal computer In addition th...

Page 3: ...l s 10 Automatic Cooling Fan 11 Inlet AC socket with Mains fuse holder 12 Temperature Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at l...

Page 4: ...he operation of connected powered appliance or connections E Battery Charger Installation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check...

Page 5: ...sorption stage Charging current will now decrease gradually until a pre set value at which the charger then automatically switches to Float Stage The max Absorption time is also controlled by the time...

Page 6: ...zation by charger itself Once Auto is selected the charger will start Equalization automatically if charger stays in Float mode for over 21 days After entering into this mode the Absorption indicator...

Page 7: ...te temp sensor at 60 C Flashing Solid ON OFF Manual power on off reset after fault cleared Alarm flash Buzzer on Bat Over Temp Fan not working or stuck Flashing Flashing OFF Manual power on off reset...

Page 8: ...ad and charger not balanced Battery does not get full charge All indicator LED work normally and sequentially OTP LED flashing Bad battery connection Battery type select switch in wrong setting Batter...

Page 9: ...ad 230V 2 5A 3 5A 5 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is...

Page 10: ...e set max power level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mou...

Page 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Page 12: ...Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Equalization mode Equalization selection slide swi...

Reviews: