background image

R&S

®

TSMA6B-BP

Battery Pack Unit

Manual

 

4900909902
Version 02

(a0èñ2)

Summary of Contents for TSMA6B-BP

Page 1: ...R S TSMA6B BP Battery Pack Unit Manual 4900909902 Version 02 a0 2...

Page 2: ...hen Germany Phone 49 89 41 29 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwar...

Page 3: ...features 9 3 Preparing for use 10 3 1 Unpacking the instrument 10 3 2 Connecting to power 10 3 2 1 Connecting to a vehicle DC power supply via cigarette lighter 10 3 2 2 Connecting to the vehicle pow...

Page 4: ...f the individual battery 22 6 4 2 Rear panel LEDs in standalone operation 23 6 4 3 Rear Panel LEDs in host controlled operation 24 6 4 4 R S TSMA6 6B web GUI tray icon only host controlled mode 24 7 T...

Page 5: ...Instructions are delivered with the product Throughout the documentation safety instructions are provided when you need to take care during setup or operation 1 1 Safety instructions The product cont...

Page 6: ...e as specified by the local waste disposal agency If you disregard these rules you risk serious personal injury or even death due to explosion fire or hazardous chemical substances The product documen...

Page 7: ...g in line with directive 2006 66 EC for disposal of batteries after they have come to the end of their service life For more information see Disposing batteries on page 30 1 3 Warning messages in the...

Page 8: ...s A printed ver sion is delivered with the product The R S TSMA6B user manual includes basic setups and typical measurement examples 2 1 2 Lihtium ion batteries safety instruction Contains safety inst...

Page 9: ...ices mobile network scanner R S TSME6 and R S TSME30DC and R S TSME44DC downconverter Usage as a power buffer for connected devices in scenarios with cracking or shortly interrupted external DC power...

Page 10: ...very is incomplete or equipment is damaged contact Rohde Schwarz 3 2 Connecting to power This section describes how to connect the R S TSMA6B BP to a power supply unit You connect the R S TSMA6B BP to...

Page 11: ...er adapter from the cable 2 Connect the open ends of the cable to the DC supply Ensure that the polarity is correct see Figure 3 1 Figure 3 1 Supplied power cable with cigarette lighter adapter 12 V D...

Page 12: ...removing the batteries To insert the batteries 1 Press one battery bay lid and open it up 2 Insert the batterie in the correct way charge indicator facing up Take care of the nut in the battery and t...

Page 13: ...first time The batteries are shipped separately with max 30 of charge Before first usage the batteries must be fully charged in the R S TSMA6B BP or with an external charger For charging batteries se...

Page 14: ...on page 6 4 1 Front panel view The front panel of the R S TSMA6B BP does not provide any connectors or con trol elements for operation Figure 4 1 R S TSMA6B BP Front panel 4 2 Rear panel view The fol...

Page 15: ...S TSMA6 BP1T and R S TSMA6 BP2T not part of the standard accessory up to four R S TSMx TSME6 TSMExxDC devices can be connected You find the connection description in the product user manuals Status LE...

Page 16: ...Instrument tour R S TSMA6B BP 16 Manual 4900 9099 02 02 You find the connection description in the R S TSMA6 TSMA6B user manuals Rear panel view...

Page 17: ...e batteries must be fully charged without an R S TSMA6B BP connected To connect the R S TSMA6 6B with the R S TSMA6B BP the following steps must be performed To connect a battery pack 1 Remove the cov...

Page 18: ...P R S TSMA6B BP 18 Manual 4900 9099 02 02 Figure 5 1 Collar screws 1 Collar screws 3 Align the collar screws with the snap in holes on the bottom of an R S TSMA6 6B and press the device down Figure 5...

Page 19: ...n holes on the bottom pane of R S TSMA6 6B 4 Move the R S TSMA6 6B to the rear side 2 until you hear a click when the collar screws are locked in Figure 5 3 Connected R S TSMA6 6B and R S TSMA6B BP BP...

Page 20: ...operation In the standalone mode the R S TSMA6B BP is used without an R S TSMA6 6B The R S TSMA6B BP handles battery charging and output power path switching The charging state of the batteries can b...

Page 21: ...SMA6 6B connected Press the power off button of the R S TSMA6 6B The R S TSMA6B BP is in standby mode In standby mode the output voltages on the R S TSMA6 6B connector and the AUX connectors are switc...

Page 22: ...eck the battery charge status during a measurement without connected DC power supply If an external DC power supply is connected or if the batteries are being charged without connected devices you can...

Page 23: ...Figure 4 2 No R S TSMA6 6B is connected and R S TSMA6 6B switched off In standalone mode the battery charge status is only displayed when an external DC power supply is connected The charge in batter...

Page 24: ...pow ered Critical charge blue BLINKING 2 Hz Charging state 10 External Power Charging green ON Battery 1 2 charg ing in progress External Power Charging fin ished green BLINKING 2 Hz Battery 1 2 char...

Page 25: ...en moving the product in a vehicle or using transporting equipment make sure that the product is properly secured Only use items intended for securing objects Transport altitude Unless otherwise speci...

Page 26: ...on is provided here Keep the batteries clean and dry If the terminals become soiled clean them with a dry clean cloth Charging batteries Charge the battery before using it for the first time Following...

Page 27: ...old battery as described in Disposing batteries on page 30 Storing batteries Ideally store the battery in the product and follow the instructions in Chapter 8 3 Storage on page 30 Otherwise observe th...

Page 28: ...ically when DC power is connected For checking the charging state see Chapter 6 4 2 Rear panel LEDs in standalone operation on page 23 To charge the batteries with an external charger 1 Press the batt...

Page 29: ...hot swapping without interrupting the mea surement on the connected devices 1 Press one battery bay lid and open it up Figure 8 1 Open battery cover 2 Remove the battery by the tab 3 Insert the batte...

Page 30: ...t that is labeled as follows cannot be disposed of in normal household waste after it has come to the end of its service life Even disposal via the munici pal collection points for waste electrical an...

Page 31: ...Dispose of batteries as specified by the local waste disposal agency Alterna tively you can contact the Rohde Schwarz local service representative For information on returning batteries to Rohde Schw...

Page 32: ...contact our customer support center A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation program ming or applicatio...

Page 33: ...s 6 Customer support 32 D Data sheets 8 H Hot swap 29 L Labels on casing 6 LED display 22 LED states host controlled operation 24 standalone operation 23 M Manual 8 O Operation mode Standalone 20 TSMA...

Reviews: