ShiftGuard

USER MANUAL

BASIC PURPOSE

The ShiftGuard PLC (Power Line Communication) 
modules are communication components for 
electric vehicle charging infrastructure. These PLC 
modems can also be used for transmission of binary 
signals in a wide range of applications. For example, 
they are used instead of conventional power cables 
to transmit information on the current tariffs of 
electricity meters. When installed in the VoltDrive 
charging infrastructure system, the ShiftGuard PLC 
modems are used to transmit information from the 
HomeGuard residual capacity meter of the electrical 
connection to the electric vehicle charging station. 
It enables the PortGuard charging control unit to 
set the charging current exactly according to the 
current available at the point of supply (at the 
distribution meter). The communication between 
the HomeGuard Residual Capacity Meter and the 
PortGuard charging control unit can also be done 
by means of RS485 twisted pair bus, however, 
such a cable is usually not installed between the 
input of the power supply point and the charging 
station. In case the installation uses the ShiftGuard PLC modems, the charging station can be placed anywhere 
after the distribution meter. When used in the tariff control system, a pair of the ShiftGuard PLC modems replaces 
the communication cable carrying information on the current tariff. PLC communication enables the distribution of 
information on the current tariff to any home appliance in a flat or a house. 

MAIN FEATURES

¬

  PLC modems for the VoltGuard system and the binary replicator 

¬

  Internal power supply of 230V AC, 50Hz

¬

  PLC_IN – a pair of digital inputs 230V AC

¬

  PLC_OUT – a pair of bistable relays 16A/230V AC

¬

  Combined input and output installation

¬

  Possibility of setting Master and Slave nodes

¬

  RS485 communication line for setting and data input

¬

  Variable system of node addressing

¬

  Possibility of data transfer through 230V Ac power network within one distribution transformer

¬

  Robust S-FSK modulation within the CENELEC D-band

¬

  LED status indication

¬

  Compact DIN rail box dimensions – 5 modules

Summary of Contents for ShiftGuard

Page 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Page 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Page 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Page 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Page 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Page 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Page 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Page 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Page 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...