Replacing the fuse
Always adhere to the safety instructions when replacing fuses!
Make sure that only fuses of the type stated and of the rated current specified are
used as a replacement. Using unsuitable or repaired fuses or bypassing the fuse
holder is inadmissible and can cause fire.
The measurement input “V/mA” (7) is protected against overcharge. The measurement input “10A” is not
protected. If measurements can no longer be made via the “V/mA” socket (7), the internal fuse must be
replaced.
Proceed as follows to change the fuse:
-
Remove all measuring lines and turn off the multi-
meter.
-
Remove the rubber holster from the housing.
-
Loosen the housing screw on the back and care-
fully slide off the battery compartment lid (11).
-
Push the plastic peg between the two battery
compartments forward until the case is unlocked.
Carefully remove the case.
-
Replace the ceramic microfuse with a new fuse of the same type and amperage. F 0.5 A / 500V
quick-acting 6.3 x 32 mm
-
Close the device in reverse order and carefully screw the battery compartment lid back on.
Disposal of used batteries/rechargeable batteries!
The end user is legally obliged (battery regulation) to return all used batteries and rechargeable batter-
ies. Disposal in the household waste is prohibited!
Batteries containing toxic substances are marked with the symbols shown that indicate
they must not be disposed of in household waste. The heavy metals concerned are: Cd =
cadmium, Hg = mercury, Pb = lead. You can return used batteries/rechargeable batteries
free of charge at the official collection points of your community, in our stores, or wherever
batteries/rechargeable batteries are sold!
You will thus carry out your legal obligations and contribute to the protection of our
environment!