OPERATION

To ensure that you start-up the converter properly, it is imperative to read this 

operations manual and the safety instructions carefully and thoroughly prior to use!
•  After the voltage converter has been properly installed, it is ready for use.  Due to the 

very low standby current consumption, an operating switch is not necessary.  As soon 

as it is turned on, the voltage converter immediately provides the necessary voltage to a 

connected 13.8 V power supply.

•  If the power supply is switched off, then the voltage converter is automatically switched to 

standby mode.

Always switch off the power supply first before connecting it to the voltage 

converter. Pay attention to the maximum power consumption. The nominal 

current must not be exceeded.

The voltage converter operates autonomously and turns off the output automatically when 

there is an overload, short circuit or a power surge. This switch-off protection is signalised by 

the red error indicator light (2).
If this light is on, then turn off the connected power supply and disconnect it from the voltage 

converter.
The voltage converter automatically detects the removal of the overload/short circuit and 

resets itself back to the standard operating mode.

Do not hook up any light sources or motorised equipment as such 

equipment/devices have a multiplied nominal current consumption. 

This could cause the voltage converter to switch to its protective scheme 

and deactivate the output.

DISPOSAL

Electronic devices are recyclable waste and must not be disposed of in the 

household waste.
At the end of its service life, dispose of the product according to the relevant 

statutory regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

BN 512309
Operating voltage ...........................................................18 - 38 V/DC
Output voltage ................................................................13,8 V/DC
Standby power consumption ..........................................<20 mA
Nominal output current ...................................................5 A
Max. output current (30 % operating load) .....................7 A
Ripple voltage (mVpp) / residual ripple (mVrms) ............<100  / <10
Load control (0-100 %) ...................................................<50 mV
Linearity ..........................................................................<50 mV
Efficiency ........................................................................>89 %
Contacts .........................................................................Flat contacts
Operating temperature ...................................................max. +50 °C
Fuse (internal) ................................................................8 A
Weight ............................................................................190 g
Dimensions (W x H x D) .................................................75 x 32 x 77 mm

BN 512310
Operating voltage ...........................................................18 - 38 V/DC
Output voltage ................................................................13,8 V/DC
Standby power consumption ..........................................<50 mA
Nominal output current ...................................................12 A
Max. output current (30 % operating load) .....................16 A
Ripple voltage (mVpp) / residual ripple (mVrms) ............<100  / <10
Load control (0-100 %) ...................................................<50 mV
Linearity ..........................................................................<50 mV
Efficiency ........................................................................>90 %
Contacts .........................................................................Flat contacts
Operating temperature ...................................................max. +50 °C
Fuse (internal) ................................................................20 A
Weight ............................................................................380 g
Dimensions (W x H x D) .................................................75 x 32 x 142 mm

Summary of Contents for SDC 2412-5

Page 1: ...rd Bei Schäden die durch Nichtbeachten dieser Bedienungsanleitung verursacht werden erlischt der Garantieanspruch Für Folgeschäden übernehmen wir keine Haftung Bei Sach oder Personenschäden die durch unsachgemäße Handhabung oder Nichtbeachten der Sicherheitshinweise verursacht werden übernehmen wir keine Haftung In solchen Fällen erlischt jeder Garantieanspruch Achten Sie auf eine sachgerechte Inb...

Page 2: ... sind Wertstoffe und gehören nicht in den Hausmüll Entsorgen Sie das Produkt am Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Bestimmungen Sie erfüllen damit die gesetzlichen Verpflichtungen und leisten Ihren Beitrag zum Umweltschutz Impressum Diese Bedienungsanleitung ist eine Publikation von Voltcraft Lindenweg 15 D 92242 Hirschau Tel Nr 0180 586 582 7 www voltcraft de Alle Rechte ein...

Page 3: ...perating instructions will result in termination of the warranty We will not assume liability for any consequential damages resulting thereof We will not assume liability for property damages or personal injury caused as a result of improper usage or non compliance with the safety instructions In any such cases any claims under the warranty will be terminated Ensure that you use the converter prop...

Page 4: ...tch off protection is signalised by the red error indicator light 2 If this light is on then turn off the connected power supply and disconnect it from the voltage converter The voltage converter automatically detects the removal of the overload short circuit and resets itself back to the standard operating mode Do not hook up any light sources or motorised equipment as such equipment devices have...

Page 5: ... il devrait a été stocké pour une période prolongée dans des conditions défavorables ou bien a été transporté dans des conditions très rudes Maniez le produit avec précaution À la suite de chocs de coups ou de chutes même de faible hauteur l appareil peut être endommagé Respecter également les informations concernant la sécurité et le mode d emploi pour les autres appareils connectés à cet apparei...

Page 6: ...e 13 8 V Si l alimentation est coupée le convertisseur de tension passe automatiquement en mode de veille Veillez à toujours couper l alimentation avant de la raccorder au convertisseur de tension Faites attention à la consommation maximale de courant Celle ci ne doit pas dépasser le courant nominal Le convertisseur de tension fonctionne de manière autonome et éteint automatiquement la sortie en c...

Page 7: ...onderhevig is geweest aan ernstige vervoergerelateerde druk Behandel het product met zorg Schokken botsingen of zelfs een val van een beperkte hoogte kan het product beschadigen Neem alstublieft ook de veiligheids en gebruiksaanwijzingen van alle andere apparaten in acht die met het product zijn verbonden Schade ontstaan door niet naleven van de gebruiksaanwijzing valt niet onder de garantie Voor ...

Page 8: ...male stroomverbruik in de gaten De nominale stroom mag niet worden overschreden De transformator werkt autonoom en schakelt de uitgang automatisch uit bij overbelasting kortsluiting of te hoge spanning Deze veiligheidsuitschakeling wordt aangegeven door het oplichten van de rode indicator 2 Brandt deze indicator schakel dan het apparaat uit en koppel het los van de transformator De transformator h...

Reviews: