Unpacking
Check all the parts for completeness and damage after unpacking.
Damaged parts must not be used for safety reasons. In case of any damage
contact our customer service..
Setting up the device
Set up the device, using the handle or the device‘s pedestal, so it can be operated and read
comfortably.
Place the device on a sturdy and solid surface.
In order to comply with the technical tolerance data, the device should be
operated for about 30 minutes within the given operating temperature range.
Ensure sufficient ventilation of the device. Do not cover or seal the ventilation
apertures of the device.
Getting started
Connect the mains cable provided to the mains connector, at the back of the device, and con-
nect the safety plug to an earthed mains socket.
Switch on the device by means of the power switch (I/0) located at the back. The device is now
internally supplied with voltage.
Press the front button once .
After a short initialization period the device is ready-for-operation. The button is illuminated.
The menu functions displayed can be selected via the buttons arranged at the sides of the
display.
Values are set with the rotary button. A value is confirmed by pressing the rotary button.
Connect the corresponding measurement lines/probes to the BNC bushings. The bushing
“OUTPUT” emits the generated signal voltage with an impedance of 50 Ohm. The output is ac-
tivated via the button Taste “Channel” or “CH1/CH2”. The button is lit if the output is activated.
Via the inputs “Input” or “In”, a supplied measuring voltage (counter / trigger
input) may only be applied to the inner conductor. The external conductor (ref-
erence earth) is connected to the earth potential (protective earth conductor).
For safety reasons the indicated maximum measurement voltage must not be
exceeded.
After finishing the measurement remove the measurement cable from the measuring object
and switch off the device.
Cleaning and maintenance
Always observe the following safety instructions before cleaning or servicing the device:
Live components may be exposed if the covers are opened or parts are re-
moved, unless this can be done manually without tools.
Prior to cleaning or repairing the device, all lines must be detached and the
device must be turned off.
Always replace defective micro-fuses with new ones of the indicated type and
rated amperage. Using repaired fuses or bypassing the fuse carrier is not per-
mitted due to safety reasons.
Do not use scouring, chemical or aggressive cleaning agents such as benzene, alcohol or
similar chemicals. These might attack the surface of the device. Furthermore, the fumes are
explosive and hazardous to your health. Moreover, you should not use sharp-edged tools,
screwdrivers, metal brushes or similar implements for cleaning.
To clean the device or the display and the measuring cables, use a clean, slightly damp, lint-
free, antistatic cloth.
If you have technical questions concerning the use of the device, feel free to
contact our technical support.
International:
www.conrad.com/contact
United Kingdom:
www.conrad-electronic.co.uk/contact
Disposal
Electronic products are recyclable material and do not belong in the household
waste. Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
You thereby fulfil your statutory obligations and contribute to the protection of the
environment!
Technical data
Item no.
1666946
1666947
1667569
Type designation
FG-1051
FG-1101
FG-1251
Sine bandwidth
5 MHz
10 MHz
25 MHz
Signal channels
1
1
2
Sampling rate
125 MSa/s
Colour LCDisplay
10.9 cm, 480 x 272 pixels
Operating temperature
+10 to +40 °C
Storage temperature
-20 to +60 °C
Supply voltage
100 – 240 V/AC, 45 – 440 Hz
Product dimension
(L x W x H) 320 x 260 x 110 mm
Weight
3.1 kg