f) AC voltage measurement
Range
Resolution
Accuracy
200.0 V
0.1 V
± (1.5 % + 7)
600 V
1 V
• Input impedance: approx. 10 MΩ.
• Frequency response: 50 - 60 Hz.
• Accuracy guarantee range: 5~100% of range, short circuit allows least significant digit
<5.
• Non-sinusoidal waveforms:
- When the crest factor is 1.0 to 2.0, the accuracy must be increased by 4.0 %.
- When the crest factor is 2.0 to 2.5, the accuracy must be increased by 5.0 %.
- When the crest factor is 2.5 to 3.0, the accuracy must be increased by 7.0 %.
• Input voltage: max. 600 Vrms.
g) Resistance measurement (Ω)
Range
Resolution
Accuracy
200.0 Ω
0.1 Ω
± (1.0 % + 5)
2000 Ω
1 Ω
± (1.0 % + 9)
20.00 kΩ
10 Ω
200.0 kΩ
100 Ω
2.000 MΩ
1 kΩ
± (2.5 % + 5)
20.00 MΩ
10 kΩ
± (2.5 % + 5)
Overload protection: 600 V
55
Summary of Contents for 2446476
Page 31: ...31...