background image

4. Connect the other side of the adapter cable to the 

connecting plug on the tripod with the 8-pin socket.

5. Follow the previous instructions for connecting the adapter 

cable and the endoscope. The sockets on the adapter 

cable are of a different size.

c) Using the reel

1. The open hook on the reel frame is for safely stowing the camera head. Before using 

the camera, remove this from the reel to prevent damage to the camera cable.

2. Handle the connection cable with care; it must not get into the reel. Slowly guide the 

endoscope camera into the pipe system to be inspected. Push the camera cable 

forwards slowly and carefully. The camera may be damaged if force is used or if you 

proceed too quickly.

3. Do not pull on the camera with force.
4. 

After you have finished inspecting, carefully guide the camera with the camera cable 

backwards and wrap the endoscope cable onto the reel. Carefully guide the endoscope 

cable backwards with your hand to prevent damage. Do not wrap the cable by turning 

the reel. Wipe the camera neck with a damp cloth before winding it back up and then 

dry it.

5. Hook the camera head into the spiral hook to prevent accidental damage during 

transport. Secure the camera head and connection socket in order to protect them 

against damage.

d) Securing/changing the protective cap

The camera is equipped with a protective cap to protect against contamination. It can be 

removed to clean the camera head.

1. To remove the protective cap, turn it in an anticlockwise direction. Do not use any 

force in order to prevent damage to the cap. You now have access to the camera 

head. Proceed in reverse order to replace the protective cap.

e) Operation

1. Turn the endoscope on.
2. Set the brightness of the camera LEDs. Information on controlling the LED brightness 

can be found in the operating instructions of the connected endoscope.

3. 

Turn off the endoscope after you have finished using it.

MAINTENANCE AND CLEANING

a) Cleaning

• 

The device does not require maintenance except for cleaning and lubrication. The ball 

bearings on the reel should be lubricated with a small amount of oil or grease from time to 

time. Use resin-free and acid-free products.

• 

Use a small brush or a cotton bud to clean the camera lens.

• 

Use a soft, antistatic and lint-free cloth to clean the device. Do not use any abrasive or 

chemical cleaning materials.

• 

Let the camera head dry before putting the camera cap on as thread protection.

• 

After inserting the camera neck into liquid, rinse it thoroughly with clean water and dry it 

before storing it for the next use.

b) Changing the camera head

The camera head on the top of the flexible cable is replaceable. Purchase a suitable 

replacement head.

• 

Begin by removing the Allen screw using the Allen key included with the product.

• 

The Allen screw is very small - stick it to a piece of packaging tape so that you will not lose 

it easily. A replacement Allen screw is included with the product. Unscrew the camera insert 

carefully in an anticlockwise direction using your hand. Grip the end of the metal spiral 

underneath the camera head.

• 

Inspect the sealing ring for damage. Replace it if it is damaged.

•  Clean the fine thread and screw holes thoroughly and remove any dirt. If necessary, use a 

small amount of light, fine mechanical oil such as sewing machine oil for the threads.

• 

Screw the new camera head into place in a clockwise direction. The connection must be 

waterproof. 

• 

Then screw the Allen screw through the thread opening into the groove on the camera 

head to fix the camera head in place. Screw the Allen screw tight enough so that it will not 

become loose and fall off when using the inspection camera.

DISPOSAL

Electronic devices are recyclable waste and must not be disposed of in the 

household waste.
At the end of its service life, dispose of the product according to the relevant 

statutory regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Camera-Ø  ............................................28 mm 
Adapter cable length .............................2 m
Image sensor ........................................CMOS

Depth of field

 ........................................5 - 60 cm

Resolution .............................................640 x 480 Pixels 
White balance .......................................Fixed setting
Exposure ..............................................Automatic
Illuminant ..............................................12 LEDs (white)
Illuminance ...........................................max. 7800 lx (at a distance of 20 mm)
Min. bending radius ..............................> 10 cm
Protection type ......................................IP67 (camera, camera neck waterproof)
Operating conditions .............................-20 to +60 °C, max. 95 % RH (non-condensing)
Storage conditions ................................ -20 to +60 °C, max. 95 % RH (non-condensing)
Camera neck length .............................25 m
Dimensions (W x H x D) .......................45 x 45 x 25.5 cm
Weight ..................................................approx. 6.5 kg

Designed for BS-1000T endoscope - Item no. 123319

 Legal notice

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing 

systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the 

time of printing. 

© Copyright 2015 by Conrad Electronic SE

V1_0215_02-DS

Summary of Contents for 1214310

Page 1: ...St e Schl ge oder dem Fall aus bereits geringer H he wird es besch digt Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der brigen Ger te an die das Produkt angeschlossen wird Ein...

Page 2: ...ndger t nach Gebrauch aus WARTUNG UND REINIGUNG a Reinigen Das Ger t ist bis auf eine Reinigung und Schmierung wartungsfrei Das Kugellager der Haspel sollte von Zeit zu Zeit mit etwas l oder Fett gesc...

Page 3: ...Jolts impacts or a fall even from a low height can damage the product Also observe the safety and operating instructions of any other devices which are connected to the product The endoscope must not...

Page 4: ...cap on as thread protection After inserting the camera neck into liquid rinse it thoroughly with clean water and dry it before storing it for the next use b Changing the camera head The camera head on...

Page 5: ...me de faible hauteur l appareil peut tre endommag Respecter galement les informations concernant la s curit et le mode d emploi pour les autres appareils connect s cet appareil Cet appareil ne doit p...

Page 6: ...cou de la cam ra apr s chaque utilisation dans des liquides avec de l eau propre et s chez la avant de la ranger pour une prochaine utilisation b Changer la t te de la cam ra La t te de la cam ra pla...

Page 7: ...e vervoergerelateerde druk Behandel het product met zorg Schokken botsingen of zelfs een val van een beperkte hoogte kan het product beschadigen Neem alstublieft ook de veiligheids en gebruiksaanwijzi...

Page 8: ...camerakop drogen voordat u de camera afdekking als bescherming van de schroefdraad monteert Spoel de camerahals na gebruik in vloeistoffen grondig af met schoon water en droog hem af voordat u hem op...

Reviews: