VOLTCRAFT 1214310 Operating Instructions Manual Download Page 3

  

OPERATING INSTRUCTIONS

VERSION 02/15

INSPECTION CAMERA WITH FIBER OPTIC CABLE AND 

REEL 25 M / 28 MM FLX LF 

ITEM NO.: 1214310 

INTENDED USE

This product is an inspection camera for the BS-1000T endoscope (not included, available 

separately), designed for optical troubleshooting or inspecting long pipe systems as well as 

machines and installations that are disconnected from a power supply. The flexible camera 

neck allows the camera on top to access inaccessible positions. The plastic camera cover 

protects the the metal camera head from accidental contact with live parts.
The reel included with the product enables the camera and the camera neck to be rolled 

up easily, and the tripod ensures that the camera stands in a secure position. The 12 LEDs 

built into the camera head allow recording in completely dark areas. The brightness can be 

gradually adjusted using the connected endoscope. The waterproof camera neck and camera 

head are designed for contact with liquids (no acids or alkaline solutions). It is forbidden to 

use the product on people and animals and in potentially explosive environments Power is 

supplied via the connected endoscope device.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If 

you use the product for purposes other than those described above, the product may be 

damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric 

shock etc. Read the instructions carefully and keep them. Make this product available to third 

parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

DELIVERY CONTENT

• 

Camera with 25 m cable and reel

• 

Holder with 1 x screw and 2 x spacer washers

• 

Screws and sealing ring kit (1 x Allen key, 3 x sealing rings, 1 x Allen screw)

• 

1 x adapter cable (5 pin to 8 pin)

• 

1 x replacement camera cover

• 

Operating instructions

SAFETY INSTRUCTIONS

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information 

on proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the 

warranty/guarantee.

a) Persons / Product

• 

The device is not a toy. Keep it out of the reach of children and pets.

• 

Do not leave packaging material lying around carelessly. These may become 

dangerous playing material for children.

• 

Protect the product from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, vapours and solvents.

• 

Do not place the product under any mechanical stress.

• 

If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed if 

the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stress.

• 

Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

• 

Also observe the safety and operating instructions of any other devices which are 

connected to the product.

• 

The endoscope must not be used in potentially explosive areas, areas carrying a 

live voltage or for inspecting people and animals.

• 

Always roll the camera neck onto the reel when it is not in use.

• 

Avoid strong vibrations. The bending radius must not be less than the minimum 

of 10 cm. 

• 

The reel is not waterproof and therefore cannot be inserted under water. Protect 

this part of the product against splashing water. 

• 

The product may only be used for inspecting facilities that do not carry a live 

voltage. The camera head is made of metal. This can lead to short circuits during 

use. For safety reasons, disconnect all parts of the facility from the power supply 

before each inspection.

• 

Only hold the camera head and camera neck in liquids that do not carry a live 

voltage.

• 

The connection sockets must not come into contact with liquids.

• 

Always use the camera with a protective cap.

• 

Attention, LED light: Do not look directly into the LED light! Do not look into the 

beam directly or with optical instruments!

• 

In industrial facilities, the accident prevention regulations for electrical equipment 

and facilities issued by the Industrial Employers' Liability Association must be 

adhered to!

b) Miscellaneous

• 

Consult an expert when in doubt about operation, safety or connection of the 

device.

•  Maintenance, modifications and repairs are to be performed exclusively by an 

expert or at a qualified shop.

If you are not sure about the correct connection or use, or if questions arise which are not 

covered by these operating instructions, please do not hesitate to contact our technical 

support or another qualified specialist.

OPERATION

Only hold the camera head and camera neck in liquids that do not carry a live voltage.
The camera neck must not be submerged beyond the "MAX Water Level" mark.
The endoscope may only be used for inspecting facilities that are not connected to a 

power source.
The camera head is made from metal and can lead to short circuits when used without 

the protective cap.
For safety reasons, turn off all power sources before each inspection.
Avoid heavy mechanical loads and vibrations. The bending radius must not be less than 

the minimum of 10 cm.

a) Securing the endoscope device to the tripod.

1. Place the product with the tripod horizontally in its working position on a level and even 

surface.

2. Insert the endoscope device (BS-1000T, not included) into the holder on the top of the 

reel.

3. Secure the endoscope using the screws in the holder.
4. Follow the above instructions in reverse order to disassemble the device.

b) Connecting/changing the inspection camera

1. Connect the adapter cable to the endoscope using the 

5-pin socket.

2. Ensure the connecting plug and socket are aligned 

properly; the key on the plug must fit exactly into the slot 

on the socket. The pins on the connecting plug fit exactly 

into the openings on the connecting socket. An arrow mark 

is printed on the connecting socket.  This arrow mark must 

point to the endoscope display.

3. Screw the metal screw cap on the plug into place in a 

clockwise direction. Unscrew the metal screw cap in an 

anticlockwise direction. Disconnect the cable by removing 

the connecting plug.

Summary of Contents for 1214310

Page 1: ...St e Schl ge oder dem Fall aus bereits geringer H he wird es besch digt Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der brigen Ger te an die das Produkt angeschlossen wird Ein...

Page 2: ...ndger t nach Gebrauch aus WARTUNG UND REINIGUNG a Reinigen Das Ger t ist bis auf eine Reinigung und Schmierung wartungsfrei Das Kugellager der Haspel sollte von Zeit zu Zeit mit etwas l oder Fett gesc...

Page 3: ...Jolts impacts or a fall even from a low height can damage the product Also observe the safety and operating instructions of any other devices which are connected to the product The endoscope must not...

Page 4: ...cap on as thread protection After inserting the camera neck into liquid rinse it thoroughly with clean water and dry it before storing it for the next use b Changing the camera head The camera head on...

Page 5: ...me de faible hauteur l appareil peut tre endommag Respecter galement les informations concernant la s curit et le mode d emploi pour les autres appareils connect s cet appareil Cet appareil ne doit p...

Page 6: ...cou de la cam ra apr s chaque utilisation dans des liquides avec de l eau propre et s chez la avant de la ranger pour une prochaine utilisation b Changer la t te de la cam ra La t te de la cam ra pla...

Page 7: ...e vervoergerelateerde druk Behandel het product met zorg Schokken botsingen of zelfs een val van een beperkte hoogte kan het product beschadigen Neem alstublieft ook de veiligheids en gebruiksaanwijzi...

Page 8: ...camerakop drogen voordat u de camera afdekking als bescherming van de schroefdraad monteert Spoel de camerahals na gebruik in vloeistoffen grondig af met schoon water en droog hem af voordat u hem op...

Reviews: