50
i) Current measurement in
μ
A and mA ranges
Currents of up to 4000
μ
A can be measured in the
μ
A measuring range and up to 400 mA in the mA
measuring range. Both measuring ranges are provided with fuses and thus protected against overload.
In the AC range, the current is measured as a true RMS value. You can switch to “AC+DC-coupled True
RMS” by pressing the yellow push button.
Proceed as follows to measure
μ
A and mA currents:
10 A MAX
μ
AmA% COM
HzV
°C
+
-
Connect the black test lead to the COM jack and the red test lead to the
•
mA/
μ
A jack.
To measure currents of up to 4000
μ
A, set the range selector switch (5) to
•
“
μ
A”; set it to “mA” for currents of max. 400 mA. After the measuring range
has been selected via the range selector switch (5), DC measurement is
automatically activated.
Now connect the two probe tips in series with the measurement object
•
(battery, circuit, etc.); the respective polarity of the measured value and
the measured value are shown on the main display (12). The active
measuring range is shown on the left subdisplay.
For AC measurements, press the blue button once. “AC True RMS”
•
appears on the display (1).
For AC measurements, the measured value is shown on the main display (12). The frequency of the
•
alternating current is shown on the right subdisplay, and the active measuring range is shown on the
left subdisplay.
Never measure currents that are higher than 400 mA in the mA/
μ
A range because this
triggers the miniature fuse.
71
Plages de mesure sur le commutateur rotatif dans le sens des aiguilles d’une
montre
VC902/VC960:
OFF
L'instrument de mesure est éteint
V
Mesure de la tension continue en volts
V
Mesure de la tension alternative en volts
mV
Hz %
Mesure de la tension continue en millivolts, mesure de la fréquence et af
fi
chage de la
puissance lors de la mesure du cycle de service
Ω
Mesure de la résistance, test de diode de continuité acoustique
Mesure de capacité
ºC / ºF
Mesure de la température
μ
A
Mesure des courants continu et alternatif en
μ
A
mA
Mesure du courant continu et alternatif en mA
A
Mesure du courant continu et alternatif en A
VC940
OFF
L'instrument de mesure est éteint
V
Mesure des tensions continue et alternative en volts
mV
Mesure de la tension continue en millivolts
Ω
Mesure de la résistance, test de diode de continuité acoustique
W
Mesure de la puissance
Mesure de capacité
ºC / ºF / Hz % Mesure de la température, mesure de la fréquence et af
fi
chage de la puissance lors de
la mesure du cycle de service
μ
A
Mesure des courants continu et alternatif en
μ
A
mA
Mesure des courants continu et alternatif en mA et mesure du courant en boucle
A
Mesure des courants continu et alternatif en A