1.  This LED Floodlight uses the latest in solid state lighting technology for 

long life, low maintenance, and high efficiency.

2.  An internal power-factor-corrected switch mode supply allows this 

fixture to be used from any nominal 100V-277V, 60Hz AC supply without 

any variation in light output.

3.  Suitable for use in:

a.  Ambient Temperatures of: -20~+40°C (-4~+104°F)
a.  Wet Locations

Note: Save these instructions for future reference.

To avoid the risk of fire, explosion, or electric shock, this product should 

be installed, inspected, and maintained by a qualified electrician only, in 

accordance with all applicable electrical codes.

To avoid electric shock:

1.  Be certain electrical power is OFF before and during installation and            

maintenance.

2.  Luminaire must be connected to a wiring system with an equipment-

grounding conductor.

To avoid explosion:

1.  Make sure the supply voltage is the same as the rated luminaire voltage.
2.  Do not install where the marked operating temperatures exceed the 

ignition temperature of the hazardous atmosphere.

3.  Do not operate in ambient temperatures above those indicated on the 

luminaire.

For supply connections use wire rated for at least 90°C (194°F).

Warning: these luminaire should ONLY be installed by a qualified electrician.

Summary of Contents for VFL-4001-LI-ABZ

Page 1: ... INSTALLATION INSTRUCTIONS Specifications and product details subject to change without notice Copyright 2017 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 1 ...

Page 2: ...oid the risk of fire explosion or electric shock this product should be installed inspected and maintained by a qualified electrician only in accordance with all applicable electrical codes To avoid electric shock 1 Be certain electrical power is OFF before and during installation and maintenance 2 Luminaire must be connected to a wiring system with an equipment grounding conductor To avoid explos...

Page 3: ...mpbody customersupport voltlighting com 813 978 3700 3 Model Input Voltage Power Factor Watt Input Current Mounting VFL 4001 LI ABZ 100 277 Volts 0 95 10W 0 3A Yoke Product Dimensions 5 5 3 25 4 75 4 5 1 75 2 5 Ø 0 75 R0 25 VFL 4001 LI ABZ ...

Page 4: ...e slot holes of the mount These marks will be used for wall anchor bolts Wall Fixture Mark Yoke Mount Install Expansion Bolts 2 Wall Anchor Bolts Drill proper holes from the marks on the wall for the wall anchor bolts Insert the wall anchor bolts into drilled holes Tighten hex nuts on the wall anchor bolts until they are fastened to the wall Hole Wall LED 120V Floodlights Yoke Mounted VFL 4001 LI ...

Page 5: ...d hex nuts Tighten until snug Fixture Bolt Wire Connections 4 Lampbody Wiring Terminal Main Supply Cable Yoke Hex Nut Washer Wall Supply Wire from Lampbody Allow enough wire from the lampbody for adjustment purposes Connect wires from the fixture into the wiring terminal The white wire goes to the Neutral terminal the black wire goes to the Live terminal and the green wire goes to the Ground termi...

Page 6: ...crews with a spanner Wall Fixture Set Screws Spanner After installation A Check whether the lighting fixture is firmly secure B Check whether all wires are connected correctly Lastly turn on the power and check if the lighting fixture works If not turn off the power and contact us at 813 978 3700 LED 120V Floodlights Yoke Mounted VFL 4001 LI ABZ ...

Page 7: ... 7 ...

Page 8: ...tails subject to change without notice Copyright 2017 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 w w w v o l t l i g h t i n g c o m Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 8 ...

Reviews: