[email protected] (58) 341-05-06 | [email protected] (58) 341-38-80 | [email protected] (22) 100-42-99
OUTPUT
SECONDARY
OUTPUT VOLTAGE
SYSTEM
FAULT
OUTPUT
PRIMARY
PV CURRENT
A
V
SOLAR
STATUS
PV VOLTAGE
OVER
HEAT
V
MPPT
MODE
SOLAR STATUS
- When the PV voltage is greater than 80% of the rated
voltage of the device, the indicator lamp will be lit. Otherwise, it will blink.
OUTPUT PRIMARY
- It lights when socket 1 is working
OUTPUT SECONDARY
- It lights when socket 2 is working
PV VOLTAGE
- Actual PV input voltage
PV CURRENT
- Actual PV input current
OUTPUT VOLTAGE
- Output voltage status, shows the actual output
voltage current of the inverter
MPPT MODE
- It lights when the MPPT mode is on
OVER HEAT
- It lights when the inverter is overheated
SYSTEM FAULT
- It lights when the PV voltage is too high or the inverter
does not work properly (continuous light) or warns of overload.