CONNECTION

URGENT!

The polarity of the supply voltage is very important while connecting PV 
panels to inverter. The reverse wiring will cause damage to the inverter and 
void the warranty!

The eco solar boost - 

Green Boost 3000

 

(DC 1210-350V)

 has two MC4 

connectors which must be connected to the PV installation. The connector 
shaped                                 should be connected to the negative pole of the PV 
installation and the connector shaped             should be connected to the 
positive pole of the PV installation.

ADC safety switch, designed for such installations, shall be installed on the 
PV system power cord. 

We connect device e.g. an electric boiler to the inverter output marked - "1".  
When the inverter detects the presence of voltage from the PV panels within 
the appropriate range, the inverter will automatically turn on. This will be 
confirmed by the LED indicator. 

Optionally,  a  second  energy  consumer  can  be  connected  to  the  inverter 
output  marked  "2".  This  can  works  only  with  a  bi-metal  thermostats. 
Electronic temperature controllers can only work with an output “1”. Lack of 
activities on both outputs for a long time will cause a delay of load sense on 
output up to several minutes. 

The  eco  solar  boost  inverter 

Green  Boost  3000

 

(DC  1210-350V

  is 

equipped  with  two  power  outputs  -  type  E  (labelled  "1"  and  "2)".  After 
connecting the correct supply voltage from the solar power system (120-
350V ), the inverter checks the presence of connected receivers. 

In  the  case  of  connecting  two  resistance  receivers,  firstly,  the  device 
connected  to  the  socket  "1"  will  be  powered.  When  the  device  stops 
consuming  energy,  the  eco  solar  boost  inverter 

Green  Boost  3000

 

(DC 

1210-350V

 will switch to power socket "2". However, if   the load on socket 

"1" will reappear, the inverter it will automatically cut the power supply to 
output "2" and start to power outputs "1".

USE

Summary of Contents for GREEN BOOST 3000

Page 1: ...LSKA Sp z o o ul Swiemirowska 3 81 877 Sopot www voltpolska pl sales voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 GREEN BOOST 3000 ECO SOLAR BOOST FO...

Page 2: ...t signals od 25 55 Storage temperature od 20 45 Weight 2 7kg 345x215x120mm with MC4 TECHNICAL DATA GREEN BOOST 3000 Congratulations on choosing our high quality eco solar boost Green Boost 3000 DC 121...

Page 3: ...t of the rst one stops receiving energy from the inverter This ensures that energy from the PV panels will not be lost when one of the units reaches a set temperature Green Boost 3000 DC 1210 350V is...

Page 4: ...of a minute Any repairs should only be carried out by an authorised service centre Do not put the voltage inverter in a high humidity area near a re source ammable substances Do not also expose it to...

Page 5: ...will be con rmed by the LED indicator Optionally a second energy consumer can be connected to the inverter output marked 2 This can works only with a bi metal thermostats Electronic temperature contro...

Page 6: ...will be lit Otherwise it will blink OUTPUT PRIMARY It lights when socket 1 is working OUTPUT SECONDARY It lights when socket 2 is working PV VOLTAGE Actual PV input voltage PV CURRENT Actual PV input...

Page 7: ...s voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 CONNECTING DIAGRAM 1 i 2 PRIMARY SECONDARY ACTIVE ONLY WHEN NO LOAD ON PRIMARY 2 1 PRIMARY SECONDARY M...

Page 8: ...ates that it is at the end of its useful life should not be disposed of with other household wastes To avoid harmful e ects on the environment and human health as a result of uncontrolled waste dispos...

Reviews: