CONNECTION
URGENT!
The polarity of the supply voltage is very important while connecting PV
panels to inverter. The reverse wiring will cause damage to the inverter and
void the warranty!
The eco solar boost -
Green Boost 3000
(DC 1210-350V)
has two MC4
connectors which must be connected to the PV installation. The connector
shaped should be connected to the negative pole of the PV
installation and the connector shaped should be connected to the
positive pole of the PV installation.
ADC safety switch, designed for such installations, shall be installed on the
PV system power cord.
We connect device e.g. an electric boiler to the inverter output marked - "1".
When the inverter detects the presence of voltage from the PV panels within
the appropriate range, the inverter will automatically turn on. This will be
confirmed by the LED indicator.
Optionally, a second energy consumer can be connected to the inverter
output marked "2". This can works only with a bi-metal thermostats.
Electronic temperature controllers can only work with an output “1”. Lack of
activities on both outputs for a long time will cause a delay of load sense on
output up to several minutes.
The eco solar boost inverter
Green Boost 3000
(DC 1210-350V
is
equipped with two power outputs - type E (labelled "1" and "2)". After
connecting the correct supply voltage from the solar power system (120-
350V ), the inverter checks the presence of connected receivers.
In the case of connecting two resistance receivers, firstly, the device
connected to the socket "1" will be powered. When the device stops
consuming energy, the eco solar boost inverter
Green Boost 3000
(DC
1210-350V
will switch to power socket "2". However, if the load on socket
"1" will reappear, the inverter it will automatically cut the power supply to
output "2" and start to power outputs "1".
USE